DPA 4410 POWER AMPLIFIER
Features
4 x 100 W output capacity
off ground potential 100 V outputs (internally configurable to 70 V/50 V or 4 ohms)
all outputs are protected against floating (no load) and short-circuit
mains supply 115/230 V AC or battery operation 24 V DC
mains switch 115/230 V
REMOTE CONTROL start with STANDBY indicator (mains and battery operation)
service mains switch
GROUND-LIFT switch
active ventilated through a temperature-controlled DC ventilator
electronically balanced inputs
routing switch for parallel operation of the amplifier inputs
input level control
power-on noise suppression
3 LED indicators with CLIPPING indicator for metering purposes
MONITOR outputs
temperature control with PROTECT indicator
fault indicators: READY and GROUND FAULT
fault message via off potential READY contact
TEST switch for pilot tone surveillance and GROUND FAULT reset
off ground potential, balanced input transformer are optionally available
pilot tone surveillance module and ground fault surveillance module are optionally available
19" rack dimensions with 3 HU
OWNER’S MANUAL
17
Seitenansicht 0
1 2 3 4 5 6 ... 14 15

Inhaltsverzeichnis

Seite 1

DPA 4410 POWER AMPLIFIER Features• 4 x 100 W output capacity• off ground potential 100 V outputs (internally configurable to 70 V/50 V or 4 ohm

Seite 2 - IMPORTANT SAFETY INSTRUCTIONS

Diagram 7 Changing the output transformer’s 354030 output voltage9. ADDITIONAL FUNCTIONS AND FEATURES9.1 NRS 90206 pilot tone surveillanceUsing the

Seite 3

Checking the functioning:With built-in NRS 90206 and operational amplifier, the READY indicators (7) have to be lit. Use the TESTbutton (3) to check a

Seite 4 - TABLE OF CONTENTS

Diagram 9 Printed circuit board 81330.1 with inserted input transformers NRS9020810. INCORPORATION INTO 19" FLIGHTCASES OR 19" RACK

Seite 5

Diagram 10 printed circuit board 85264.2 with inserted DC fuses F502 and F507Changing the fuses F502 and F503:The battery fuses F 502 and F503

Seite 6 - ON OFF

12. SPECIFICATIONS OF THE DPA 4410Mains supply:Voltage: 115 V / 230 V~ AC, ±10Frequency: 50 - 60 Protection class: Imains supply U

Seite 7

Monitor output characteristics: unbalancedNominal output voltage 2 V = +8.2 dBuNominal load impedance 600 ohmsOverall frequency response 6

Seite 8

The lightning flash with arrowhead symbol, within anequilateral triangle is intended to alert the user to thepresence of uninsulated “dangerous voltag

Seite 9

INDICATORS, CONTROLS AND CONNECTIONS 1 LED meters 2 CLIP indicator 3 TEST button for checking and reset 4 STANDBY indicator 5 PROTECT indicator

Seite 10

TABLE OF CONTENTS FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Seite 11

1. GENERAL NOTESThe amplifier DPA 4410 has been specially designed to ensure durable performance and reliableoperation of sound reinforcement systems

Seite 12

4. INPUTS 1 - 4The inputs 1 - 4 (14) are electronically balanced. With a sensitivity of 775 mV = 0 dB, they are meant forthe connection of common cont

Seite 13

5.2 POWER OUTPUT with 100 V speaker systemsThe use of speaker systems with a 100 V matching transformer is recommended to reduce the lack inperforman

Seite 14

5.4 POWER OUTPUT 100 V with double output capacityIf the output power of one output is not sufficient to feed all cabinets that are incorporated with

Seite 15

Diagram 6 Pin-assignment of the REMOTE CONTROL D-Sub connector 6. METERINGThe green LED indicator (1) permits the continuous monitoring of the outpu