ZONEX COMMON
36
35
34
32
31
30
28
27
26
25
24
EARTH
COMMON
BATTERY NEGATIVE ONLY
BATTERY POSITIVE ONLY.
RELAY A
RELAY B
RELAY C
+ AUX POWER
CLASS 2 TRANSFORMER
16.5 VAC 40 VA 60 Hz
Model D1640
Internally Fused - Do not short
Requires Unswitched Outlet
Do not share with other equipment
.
S4 GROUND FAULT DETECT
Enabled
Disabled
RED
ON when communicating
OFF when idle
Commercial Protected-Premises Control Panel
System is intended to be checked by a Qualified Technician at least every 3 years.
The types of initiating circuits the control panel has been approved for are A, M, W, SS.
The types of signaling the control panel has been approved for are DAC, OT, NC, RevPol.
VOLTAGE RANGES
Open 3.7 - 5.0 VDC Short 0.0 - 1.3 VDC
Normal 2.0 - 3.0 VDC
SDI
RED
POWER +
YELLOW
DATA BUS A
GREEN
DATA BUS B
BLACK
COMMON
ZONEX OUT 1
ZONEX IN 1
NFPA
Style 4.0
Signaling
Line
Circuits
F01U267744-00a
LEDs Off when Normal
YELLOW - Charging Status
RED - Low Battery - 12.1 VDC
10.2 VDC - Battery Load Shed
This equipment should be installed in accordance with the NFPA 70 (National Electrical Code) and
NFPA 72 (National Fire Alarm Code).
D9412GV4
ZONEX POWER +
PHONE LINE SEIZED LED
TIP
RING
TELCO CORD MODEL D161
POWER SUPPLY REQUIREMENTS
The Power Supply provides a maximum of 1.4 Amps
for the Control Panel and all Accessory Devices. For
System Loading, refer to the GV4 Series Control
Panel Installation and Operation Guide.
All external connections except Terminal 5 (battery positive) are inherently power
limited. Requirements for battery standby time might reduce allowable output.
WARNING!
Multi-Battery installation requires
Model D122 or D122L Dual Battery
Harness. Improper installation can
be a fire hazard.
Battery: Replace every 3 to
5 years with one or two Model
D126 or D1218 12 V Lead Acid
Batteries.
PROGRAMMABLE
ALARM OUTPUTS
Terminals
SWITCHED AUX
and
Terminal
8
Operation
Monitor
LED
Pulses when
Normal
Flickers when
Ringing
GREEN
Point 3
Point 4
Point 1
Point 2
1211 13
Point 5
Point 6
Point 7
Point 8
Incorrect wiring will
damage this equipment.
Suitable for dry indoor
use only.
Devices powered by any
power output must
be supervised.
Minimum system requirements for Classification in accordance with ANSI/SIA CP-01-2010
UL Listed and Classified control unit Model D9412GV4, D7412GV4, or D7212GV4;
UL Listed and Classified keypad Model D1256, D1257, D1260, D1255, D1255R, or D1255RB;
UL Listed Local Bell
WARNING!
To prevent risk of
electric shock,
disconnect AC power
and telephone lines
before servicing.
CAUTION:
Avoid damage to Panel.
Do not connect 24 V to terminals.
Maximum charging current 1.4 A
ZONEX OUT 2
ZONEX IN 2
Not suitable for remote station protected premises services where separate transmission circuits
are required for fire, supervisory (when applicable) and trouble signals when using D185.
The D9412GV4 Control Panel is UL Listed For Central Station, Remote Station, Local, Auxiliary,
Proprietary, and Household Fire Alarm, and Central Station, Local, Proprietary,
Police Station Connect, Household Burglar Alarm
and Encrypted Line Security when
communicating via a network.
SDI2
RED
POWER +
YELLOW
DATA BUS A
GREEN
DATA BUS B
BLACK
COMMON
10
8
7
6
5
3
2
1
6
7
Refer to GV4 Series Control Panels Approved Applications Compliance Guide for
System Wiring Diagram, Issue A and for compatible smoke detectors, 2-wire
Compatible Identifier A.
SDI Connector
SDI2 Connector
14
16
15
18
19
17
20 22
21
9
23
29
33
4
D9210C Access Module
GV4 Series Control Panel connection to D9210C Access Module with ARD-FPBEPIC-OC BioEntry Plus reader
SDI BUS
SDI BUS
To Door Contact
1K EOL
RTE/REX
Normal Open
Pin 3 Wiegand Output
White
Green
Pin 5 Power & RS485
Red
Pin 3 & 5 (Black)
Bio Entry Plus
ARD-FPBEPIC-OC
COM
A
BPWR
NC
C
NO
COM COM
T+
ZN+ RTE REX
12V 5.2V
DATA
0
DATA
1
BUZZ LED
3
1
2
0
7
6
5
4
8
9
TENS
3
1
2
0
7
6
5
4
8
9
ONES
READER
SDI
RELAY
FLASH PORT
To Listed Keypad
(D1265 - D1260/B - D1255/B -
D720/B)
Required BioEntry Plus connections
are listed above.
See ARD-FPBEPxx-OC_EN
Installation Manual (v1.1, 2010.10)
for additional instructions