Bosch D7412GV2 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Sicherheitszugriffskontrollsysteme Bosch D7412GV2 herunter. D7412GV2 Control Panel - Bosch Security Systems Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 7
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Intrusion Alarm Systems | D7412GV2 Control Panel
D7412GV2 Control Panel
www.boschsecurity.com
u Fully integrated intrusion, fire, and access control
allows users to interface with one system instead of
three
u Conettix IP‑based communication option provides
high‑speed, secure alarm transport and control
u Eight programmable areas with perimeter and
interior partitioning
u 75 points with flexible configuration options to meet
multiple installation requirements
u Your choice of vacuum fluorescent or ATM‑style user
interface keypads
The D7412GV2 Control Panel provides an integrated
solution for intrusion, access control, and fire alarm
system applications. The control panel includes a
communicator that sends event reports to selected
public switched telephone network (PSTN) or IP
network destinations through four programmable
route groups. The control panel provides up to 75
individually identified points. Each point:
Accommodates normally‑open (NO) and
normally‑closed (NC) devices with end‑of‑line (EOL)
resistor supervision
Is programmable for fire, fire supervisory, or intrusion
applications.
With the D7412GV2 you can:
Monitor alarm points for intruder or fire alarms while
operating user keypads and other outputs
Program all system functions on‑site through a D5200
Programmer or remotely through Remote
Programming Software (RPS).
Add up to two doors of access control using the
optional D9210BLC Access Control Interface Module.
Functions
Programmable Outputs
2 A alarm power at 12 VDC
1.4 A auxiliary power at 12 VDC
Four alarm‑output patterns
Automatic bell test
Programmable bell shut‑off timer
System Response
31 custom point indexes, including fire supervisory
Selectable point response time
Cross point capability
Fire alarm verification
Fire inspector’s local test
Watch mode
Scheduled events (skeds) arm, disarm, bypass and
unbypass points, control relays, control authority
levels, and control door access
User Interface
Supervision of up to eight keypads (up to 32
unsupervised keypads can be used)
Custom keypad text
Full function command menu including custom
functions
Authority by area and 16‑character name for each
user
14 custom authority levels control user’s authority to
change, add, or delete passcodes or access control
credentials; to disarm or bypass points; and to start
system tests
Seitenansicht 0
1 2 3 4 5 6 7

Inhaltsverzeichnis

Seite 1 - D7412GV2 Control Panel

Intrusion Alarm Systems | D7412GV2 Control PanelD7412GV2 Control Panel www.boschsecurity.com u Fully integrated intrusion, fire, and acce

Seite 2

NoticeUse at least one keypad in each system.Area ConfigurationsArea programming offers a wide selection of differentsystem configurations. Each area

Seite 3

Scheduled Events (Skeds)The internal clock and calendar start individuallyscheduled events (skeds). Skeds perform functionssuch as arm or disarm, rela

Seite 4 - 4

Magnetic Contacts Bosch magnetic contacts include recessed,terminal connection, miniature, overhead door,and surface mount.Modules C900V2 Dialer Captu

Seite 5

ISW‑EN1233D Necklace Pendant Transmitter(Double‑button) ISW‑EN1233S Necklace Pendant Transmitter(Single‑button) ISW‑EN1235D Beltclip Pendant Trans

Seite 6

D7412GV2 Kit Ordering Information KitsComponents D7412GV2-A D7412GV2-CA-A D7412GV2-B D7412GV2-C D7412GV2-CA-C D7412GV2-DD7412GV2 Board1 11 1D7412G

Seite 7

D1640-CA TransformerFor use in Canada. System transformer rated at16.5 VAC, 40 VA.Order number D1640-CAD8103 EnclosureGrey steel enclosure measuring 4