WARNING: Improper installation,
adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual. For
assistance or additional information consult a qualified
installer, service agency or the gas supplier.
Upon completion of the installation, these instructions
should be handed to the user of the appliance for future
reference.
In the Commonwealth of Massachusetts this product
must be installed by a licensed plumber or gas fitter.
FEATURING: Electronic Ignition and Power Venting
INSTALLATION AND OPERATING INSTRUCTIONS FOR AUTOMATIC
INSTANTANEOUS TYPE WATER HEATER FOR USE WITH NATURAL AND
LIQUEFIED PETROLEUM GAS
MODEL 125FX LP and 125FX NG
(Flow Modulated with Electronic Ignition and Power Venting)
Suitable for heating potable water only
Not approved for space heating purposes
Intended for variable flow applications with steady cold water inlet temperatures
WARNING
If the information in this manual is not followed exactly. A
fire or explosion may result causing property damage,
personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable,
combustible or corrosive vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
- Close gas valve. Open windows.
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any
phone in your building.
- Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Specifications............................................. Page 2
Rules for safe operation ........................... Page 4
Locating the Heater .................................. Page 4
Combustion Air Requirements ................ Page 5
Mounting the Heater ................................. Page 6
Venting the Heater .................................... Page 7
Gas Connections ....................................Page 10
Water Connections .................................Page 12
Electrical Connections ........................... Page 13
Safety before turning on the heater .... Page 14
Lighting and Operating instructions ....Page 14
Setting water temperature .....................Page 14
Maintenance & Service.......................... Page 15
Trouble Shooting...................................... Page 16
Diagram of AquaStar ............................. Page 20
Components and Parts List .................. Page 22
Warranty ................................................... Page 25
TABLE OF CONTENTS
6 720 606 601 US (04.10) AL
Seitenansicht 0
1 2 3 4 5 6 ... 25 26

Inhaltsverzeichnis

Seite 1 - MODEL 125FX LP and 125FX NG

WARNING: Improper installation,adjustment, alteration, service or maintenance can causeinjury or property damage. Refer to this manual. Fora

Seite 2 - UNPACKING THE AQUASTAR HEATER

10 6 720 606 601Fig. 6 - Appliance pressure regulator(with directional arrow on reverse side pointing up)GAS LINE SIZINGThe pressure regulator provide

Seite 3 - AQUASTAR MODEL 125FX

116 720 606 601GAS PIPING, CONNECTIONSBefore connecting the gas supply, check the rating plate on the right side of the front cover to be sure that th

Seite 4 - FOR SAFE OPERATION

12 6 720 606 601Fig.7 - Water valve and water connectors, top viewWATER CONNECTIONSInstall the heater centrally in the building if possible andmake ho

Seite 5 - CLEARANCES

136 720 606 601ELECTRICAL CONNECTIONSWARNING: For safety reasons, disconnect the power supply to the heater before any service or testing is perf

Seite 6 - MOUNTI NG INSTALLATION

14 6 720 606 601OPERATING INSTRUCTIONSBefore operating the heater, make sure that the system isfilled with water.Open the cold water inlet supply to t

Seite 7 - 76 720 606 601

156 720 606 601Fig. 12 - Characteristic Pilot FlameFlame sensorPiezoElectrodeWater Valve (Part # 8707002802): The water valve onthis heater should b

Seite 8 - 8 6 720 606 601

16 6 720 606 6013. Water flow is not sufficient to activate heater.Water flow rate at faucet is below minimum flow needed toactivate heater. When temp

Seite 9 - 96 720 606 601

176 720 606 601Mineral deposits can eventually (3-5 years in hard waterareas) corrode the water valve parts to a point where theywill need replacing.

Seite 10 - GAS CONNECTIONS

18 6 720 606 601WATER IS TOO HOT1. Temperature Selection too highTurn the temperature adjustment knob counter-clockwise(to the left) to lower the

Seite 11 - FOR LP GAS

196 720 606 601

Seite 12 - WATER CONNECTIONS

2 6 720 606 601AquaStar 125FX LP and 125FX NG SpecificationsWater Connection 1/2” Thread fitting NPTH x W x D 29 3/4” x 18 1/4” x 8 3/4"Vent 4”G

Seite 14 - SETTING THE WATER TEMPERATURE

216 720 606 601Fig. 15 - Diagram of AquaStar 125FX1. Heat exchanger2. Pilot assembly3. Burner manifold gaspressure test nipple4. Main gas burner5. Pil

Seite 15 - THE BACK OF THIS MANUAL

22 6 720 606 601Fig. 16 - INTERIOR COMPONENTS DIAGRAM AND PARTS LIST

Seite 16 - NO SPARK AT THE PILOT

236 720 606 601Fig. 16INTERIOR COMPONENTS DIAGRAMAND PARTS LIST 125FX1 Cover 8 705 421 7752 Temperature adjustment knob 8 702 000 1113 Temperature adj

Seite 17 - 176 720 606 601

24 6 720 606 601Fig. 17 - Flow chart of Aquastar 125 FX

Seite 18 - 18 6 720 606 601

256 720 606 601LIMITED WARRANTYAquastarGeneralAquastar water heaters are warranted by the Manufacturer(BOSCH) through Controlled Energy Corp. Contro

Seite 19 - 196 720 606 601

Replacement Parts available from North AmericanDistributorCONTROLLED ENERGY CORP.340 Mad River ParkWaitsfield, Vermont 05673Phone 800-642-3111Fax (802

Seite 20 - 20 6 720 606 601

36 720 606 601MINIMUM INSTALLATION CLEARANCES FROM COMBUSTIBLE AND NONCOMBUSTIBLE MATERIALS FOR ALCOVE OR CLOSET INSTALLATIONSFRONT VIEW SIDE VIEWAQUA

Seite 21 - Diagram of AquaStar 125FX

4 6 720 606 601GENERAL RULES TO FOLLOWFOR SAFE OPERATION1. You should follow these instructions when you install yourheater. In the United States: The

Seite 22 - 22 6 720 606 601

56 720 606 601COMBUSTION AIR REQUIREMENTSThe AquaStar water heater holds cold water in its copperheat exchanger and brass water valve when not in use.

Seite 23 - AND PARTS LIST 125FX

6 6 720 606 601Fig. 3 - Incandescent Particle Tray IllustrationThe incandescent particle tray (shipped loose in the cartonwith the water heater) must

Seite 24 - 24 6 720 606 601

76 720 606 601VENTINGWARNING: Do not reduce the vent pipe size anddo not common vent with any other vented appliance orstove.This appliance must be ve

Seite 25 - LIMITED WARRANTY

8 6 720 606 601Fig 4: Some Venting Guide SuggestionsAn approved side wall vent terminal must be used when the water heater is vented through a sidewal