14
Power Xpress™ Bollard Charge Station
Installation Guide
EL-50600-17 Rev. A
CAUTION: Read all instructions before installing
the EVSE.
WARNING: Main service power must be
off and disconnected before attempting
to install the EVSE.
WARNING: The bollard weighs 20 lb per
foot, and the bottom end is signicantly
heavier than the top end. Take proper
precautions and use safe lifting practices
when lifting the bollard.
CAUTION: All adapter and connection ttings
must be classied as liquid-tight. The following
types of exible conduit are recommended:
LFMC (liquid-tight exible metal conduit),
LFNC-B (liquid-tight exible nonmetal conduit),
or LFNC-A (liquid-tight fexible nonmetal
conduit).
1. Place the bollard where it is to be installed and
drill holes.
2. Install the 3/4 in. anchor bolts in accordance
with industry standards for the type of
mounting being performed.
A
B
A. Conduit stand pipe
B. Marked locations for anchor bolts
Figure 12. Drill Holes
NOTE: Depending on the type and size of the con-
duit stand pipe, a variety of adapters may
be used to convert the stand pipe to 1/2-in.
liquid-tight exible conduit.
3. Slide the wires through the required adapters
and the 1/2-in. liquid-tight exible conduit.
4. Install 1/2-in. liquid-tight exible conduit to the
conduit stand pipe.
NOTE: Consult national and local codes for ap-
proved, liquid-tight exible conduit.
B
C
D
A
A. 1/2-in. liquid-tight exible conduit
B. Liquid-tight tting
C. Threaded adapter
D. Conduit stand pipe
Figure 13. Stand Pipe Conduit Connection
Kommentare zu diesen Handbüchern