4.2.2 Filter and bandwidth configuration
The BMA220 has a digital filter that can be configured by setting the corresponding register bits
filter_config[3:0] at address 0x10 (SPI) / 0x20 (I
2
C). For compatibility reasons the settings
are defined based on BMA120. To always ensure an ideal cut off frequency of the filter the
BMA220 is adjusting the sample rate automatically.
Table 6: Digital filter configuration
filter_config[3:0]
0x5 0x4 0x3 0x2 0x1 0x0
digital filter cut-off frequency
32Hz 64Hz 125Hz 250Hz 500Hz 1kHz
The internal SC-filter has a fix cut-off frequency at 1 KHz. In addition to the internal SC-filter a
digital filter is available which is providing a filtered and an unfiltered data stream for all of the 3
axes of acceleration.
If application specific reasons require a bandwidth configuration <32Hz, please contact your
Bosch Sensortec representative.