Bosch DIVAR AN 3000 Installationsanleitung

Stöbern Sie online oder laden Sie Installationsanleitung nach Digitale Videorecorder (DVR) Bosch DIVAR AN 3000 herunter. Bosch DIVAR AN 3000 Installation guide [en] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - DIVAR IP 3000

DIVAR IP 3000DIP-3040-00N, DIP-3042-2HD, DIP-3042-4HD en Quick Installation Guide

Seite 2

System overviewThe DIVAR IP 3000 system is an affordable and easy to use all-in-one recording, viewing, and management solution for networksurveillanc

Seite 3 - Table of contents

Device viewsThere are several LEDs on the front and rear of the chassis. TheLEDs show the over-all status of the system and the activity andhealth of

Seite 4 - Safety precautions

Rear view:162 3 45 71 1x VGA (monitor) 5 Mains connection 100 -240 VAC2 1x Ethernet (RJ45) 6 1x USB 3.0Note: Do not use this portfor keyboard and mous

Seite 5

4If the system is onlyconnected to the DVIport, no video signal isdisplayed until the systemhas started completely.This can take 1 – 2minutes. A video

Seite 6

LEDindicatorLEDcolorLEDstateDescriptionBlue Blinking System is booting or shuttingdownRed On Critical event occurred, suchas degraded RAID volume.Bosc

Seite 7 - Electrical safety precautions

Nr. LEDindicatorLEDcolorLEDstateNIC state1 RJ45 LED(left)N/A Off No connection or 10Mb/sGreen On 100 Mb/sYellow On 1000 Mb/s2 RJ45 LED(right)Yellow On

Seite 8 - ESD precautions

System setup - first stepsThe following installation directive provides information onInstallation and Configuration.DIVAR IP systems are based on Win

Seite 9 - Operating precautions

User with administrator rights:– User: BVRAdmin– Password: WSS4BoschNotice!We strongly recommended not changing the user settings.Changing the user se

Seite 10 - System overview

A series of scripts perform important setup tasks. This cantake several minutes. Do not turn off the computer.A page is displayed where you can perfor

Seite 11 - Device views

– Using Bosch VMS Configuration Client, page 30– Additional Documentation and client software, page 33Using Bosch VMS Configuration WizardIntended use

Seite 13 - LED description - front panel

Welcome pageIf the connection to the Management Server cannot beestablished, a corresponding error message is displayed. Youcannot continue working wi

Seite 14

Network settings pageYou configure the network settings of the operating system.As soon as you click Next button, the settings are activated. If you h

Seite 15

Time settings pageYou configure the time settings of the operating system. 22 en | System setup - first steps DIVAR IP 30002013.09 | V4 | DOC Bosch S

Seite 16 - System setup - first steps

Video settings pageThis page displays the devices and services that are included inthe latest saved configuration. You can import a configuration. DI

Seite 17 - Starting the application

Device selection pageThis page displays all video devices that are not included in thelatest saved configuration.Deselect the devices that should not

Seite 18

Device passwords pageThis page is used to authenticate password protected devices.This can either be done for all cameras at once (if passwordsare ide

Seite 19

Recording profile pageFor different profile assignments to different cameras you mustexecute Configuration Wizard multiple times.Note:Before selecting

Seite 20

All video devices use the default settings for Stream 1 torecord.To change these use the Bosch VMS Configuration Client.– ScheduleThe default schedule

Seite 21

Add storage pageThis page allows the addition of additional iSCSI storage devicesFor limitations, refer to the datasheet available in the onlinecatalo

Seite 22 - Time settings page

User accounts pageYou can add users and passwords. Use Configuration Client toadd user groups and to change permissions. DIVAR IP 3000 System setup -

Seite 23 - Video settings page

Table of contents1Safety precautions 41.1 General safety precautions 41.2 Electrical safety precautions 71.3 ESD precautions 81.4 Operating precaution

Seite 24 - Device selection page

Finish configuration pageAfter clicking Save and activate the configuration is activated.After successful activation the Activate Configuration page i

Seite 25

The application performs a network scan for all defaulteddevices.4. To assign all devices at once, click Select All, then right-click the selected dev

Seite 26

Note:Cameras in the image window with a red dot in thecamera’s icon are viewed live.To verify recording functionality in the Operator Client4 Cameras

Seite 27

Additional Documentation and clientsoftwareDocumentation for Bosch Security System products can befound as follows:4 www.boschsecurity.com > select

Seite 28

End-user license agreement (EULA)This chapter informs you about the Microsoft License Terms forMicrosoft Windows Storage Server 2008 R2 Standard.Pleas

Seite 29 - User accounts page

DIVAR IP 3000 End-user license agreement (EULA) | en 35Bosch Sicherheitssysteme GmbH 2013.09 | V4 | DOC

Seite 30

36 en | End-user license agreement (EULA) DIVAR IP 30002013.09 | V4 | DOC Bosch Sicherheitssysteme GmbH

Seite 31

DIVAR IP 3000 End-user license agreement (EULA) | en 37Bosch Sicherheitssysteme GmbH 2013.09 | V4 | DOC

Seite 32

38 en | End-user license agreement (EULA) DIVAR IP 30002013.09 | V4 | DOC Bosch Sicherheitssysteme GmbH

Seite 33

DIVAR IP 3000 End-user license agreement (EULA) | en 39Bosch Sicherheitssysteme GmbH 2013.09 | V4 | DOC

Seite 34

Safety precautionsObserve the safety precautions in this chapter.General safety precautionsFollow these rules to ensure general safety:– Keep the area

Seite 35

40 en | End-user license agreement (EULA) DIVAR IP 30002013.09 | V4 | DOC Bosch Sicherheitssysteme GmbH

Seite 36

DIVAR IP 3000 End-user license agreement (EULA) | en 41Bosch Sicherheitssysteme GmbH 2013.09 | V4 | DOC

Seite 37

42 en | End-user license agreement (EULA) DIVAR IP 30002013.09 | V4 | DOC Bosch Sicherheitssysteme GmbH

Seite 39

Bosch Sicherheitssysteme GmbHRobert-Bosch-Ring 585630 GrasbrunnGermanywww.boschsecurity.com© Bosch Sicherheitssysteme GmbH, 2013

Seite 40

!Warning!Removing the housing:To avoid electric shock, the housing must only be removed byqualified service personnel.Before removing the housing, the

Seite 41

!Warning!Handling of lead solder materials used in this product mayexpose you to lead, a chemical known to the State of Californiato cause birth defec

Seite 42

Electrical safety precautionsBasic electrical safety precautions should be followed to protectyou from harm and the system from damage:– Be aware of t

Seite 43

new fuse must be the same or equivalent as the onereplaced. Contact technical support for details andsupport.!Caution!Mainboard Battery: There is a da

Seite 44

– Handle a board by its edges only. Do not touch itscomponents, peripheral chips, memory modules orcontacts.– When handling chips or modules, avoid to

Kommentare zu diesen Handbüchern

Keine Kommentare