>> HISTORY LOG SETUP
•Select Yes for those events that you want to log in the history file.
The entire history list is erased if you select the Clear History item.
Date/time changes of stored video are always logged and cannot be
disabled or cleared.
>> LOCAL PASSWORDS
Set or change the password that allows access to playback functions.
Set or change the password that allows access to the configuration
functions.
Use the camera keys (1 to 9) on the front of the unit to enter a four-digit
password in the dialog box that appears.
Enter the same password again to have it verified.
Press F2 to remove password protection.
>> CONNECTIVITY
The Connectivity menu gives access to settings that control the behavior of the
unit with respect to all external devices or a network. It also gives access to
settings for connecting computers via the communications port.
>>> Network setup
Set DHCP to Yes to have IP address, subnet mask and default
gateway assigned automatically by the network server. The actual
values are displayed.
Enter a Divar name to be used in the network.
Fill in the IP, subnet mask and default gateway addresses when
DHCP is set to No. If required, change the default http port (80) to
a new value. The MAC address is read only.
•If Discovery is set to Enabled, the Control Center can carry out
automatic discovery and read the IP address of the unit.
Restrict the network bandwidth by entering an Mbps between 0
and 100 for the bandwidth limit.
>>> Network access
Access to the unit via the network can be set for up to two different
users.
Restrict access to the unit by listing an IP address range. The range
you use will normally depend on your network setup.
The administrator is user 1 and is identified as
ADMINISTRATOR.
IP Range
Eight IP ranges can be entered to allow access.
Enter the same begin and end address to specify a single IP address.
Enter different begin and end addresses to specify an IP address
range.
Use the up/down arrow keys to move to an IP entry. Press the select
key to edit the entries. Press F1 to set the default values
(000.000.000.000 to 255.255.255.255).
Users
Enter a name, up to 16-characters long, for each user. Enter a
password up to 12-digits long.
Set User Rights to Live to restrict viewing rights to live video only.
Select the cameras in the Camera Lock Out submenu that are not
accessible for the user.
Set the camera sequence dwell time (from 3 to 59 seconds) for the
remote viewer.
Set Camera Control to allow control of controllable cameras
remotely.
>>> COM port
The COM port is an RS232 serial port used mainly for connecting
a PC to the unit.
Most parameters are fixed. Select the appropriate baud rate.