2.3 Main applications
LE10 Radio Receiver as small stand alone call system
After receiving a radio signal from a programmed radio
transmitter, the relay output switches a siren or a lamp to
indicate locally a wireless call.
LE10 Radio Receiver connected to a emergency call system
via relay contact
After receiving a radio signal from a programmed radio
transmitter, the relay will be switched. This relay output is
connected to a wired emergency call system by wire and hereby
a call will be generated or forwarded.
LE10 Radio Receiver as part of a Resident Alert System
monitoring dementia
After receiving a signal from a dementia transmitter, the relay
will be activated to close a monitored door.
2.4 Description of the different modes
Mode Name Description
1 Normal 20 wireless transmitters can be programmed.
Calls are indicated by the red LED and Relay 1.
A battery-low signal is indicated by the red
LED and Relay 2.
2 Normal, with red LED
deactivated at
battery-low indication
The same functions as in mode 1 are available,
except for the battery-low signal which is not
indicated by the red LED, but only by Relay 2.
3 Dementia The MIYS37L and MIYS37E wireless
transmitters are detected. Relay 1 can be used
to lock a monitored door. Relay 2 can be used
to interrupt a monitoring loop.