Bosch RFRC-OPT Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Empfänger Bosch RFRC-OPT herunter. Bosch RFRC-OPT Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - RADION receiver OP

RADION receiver OPRFRC-OPT en Reference Guide

Seite 2

RADION receiver OPRADION receiver OP is a wireless receiver that connects RADION wireless peripherals tosupported Bosch option bus control panels via

Seite 3 - Table of contents

– As a consumer, you are legally obliged to take batteries to a suitable collection point.– You can return used batteries free of charge to the point

Seite 4

Figure 3.1: Address switch set to 1Option Bus address settingsDepending on the supporting control panel, use the following table as a reference whense

Seite 5 - Introduction

Notice!Do not install long cable runs next to high-current power feeds. Keep cable lengths as shortas possible to minimize noise pickup.Ensure that th

Seite 6

The preferred method of entering in the RFID number would be to enter it in manually via thekeypad – point source/RFID, or remote programming software

Seite 7 - General installation

MaintenanceAt least once a year, a walk test should be performed to verify the range and coverage forproper operation.Magnet walk testPerform a magnet

Seite 8

Communication error state:The receiver enters a communication error state when, during power up, it does not establisha link with the control panel, o

Seite 9 - Maintenance

Relative Humidity Up to 93% non-condensingFrequency 433.42 MHzWiring Distance Maximum distance of 300 m (1000 ft) fromthe control panelWiring Gauge 0.

Seite 10

RADION Device Battery Size Battery Type Cell Voltage Quantity(Cells)RFKF-TB key fobRFKF-FB-key fobCR2032 (coincell)Lithium 3 VDC 1RFPB-SB- panicbutton

Seite 11 - RFRC-OPT Installation

RADION repeaterThe RFRP is a combined receiver and transmission device that improves the overalltransmission, communication, and reliability capabilit

Seite 13

SpecificationsDimensions 139.70 mm x 209.60 mm x 31.80 mm(5.50 in x 8.25 in x 1.25 in)Power/Voltage(Standby battery)16.5 VAC, 40VA (~)Rated 3.7 VDC, 3

Seite 14 - Walk test

RADION glassbreakThe RFGB is a wireless transmitter used for detecting breaking glass. Throughout thisdocument, the term “glassbreak” refers to glass

Seite 15 - External LED states

– For armor-coated glass installations, mount the sensor no more than 12 ft (3.65 m) fromthe glass– Mount the detector in the direct line of sight of

Seite 16 - Specifications (RFRC-OPT)

Notice!If blinds or drapes are present, test the area by holding the hand-held tester behind theclosed blinds or drapes.Sensor testThe sensor must be

Seite 17 - Battery requirements

The specified range of the sensor has been established for worst-case conditions. While thesensor will likely function at additional range, it may mis

Seite 18

RADION TriTechThe RFDL-11 is a motion detector which uses artificial intelligence to detect motion andprovide immunity to false alarms. An integral RF

Seite 19 - RADION repeater

2.1 m (7.0 ft) -9゚ -6゚2.4 m (8.0 ft) -10゚ -7゚Notice!The mounting height must be 2 m (6.5 ft) and the vertical angle must be set at -5゚ forinstallation

Seite 20 - Specifications

LED Condition CauseFlashing blue Warm-up period after power-upNo LED upon initial power up PIR failure. Replace unit.Walking Testing the system1. Star

Seite 21 - RADION glassbreak

RADION PIRThe RFPR-12 is a high performance PIR motion detector that uses advanced signal processing.An integrated wireless transmitter sends a batter

Seite 22 - Test the sensor

Notice!In the normal operating mode, an alarm can be transmitted only after three (3) minutes havepassed since the previous alarm restoral. This 3 min

Seite 23

Table of contents1Introduction 51.1 About documentation 51.2 Bosch Security Systems, Inc. product manufacturing dates 52General installation 72.1 Inst

Seite 24 - Hand clap test

RADION PIR CThe RFPR-C12 is a high performance curtain PIR motion detector that uses advanced signalprocessing to provide outstanding catch performanc

Seite 25 - RADION TriTech

Notice!In the normal operating mode, an alarm can be transmitted only after three (3) minutes havepassed since the previous alarm restoral. This 3 min

Seite 26 - Walk testing

RADION smokeThe RFSM is a non-latching wireless smoke detector that sends an alarm signal to the receiver.The following features include:– A visual st

Seite 27 - RADION TriTech

1 ᅳ High intensity LED2 ᅳ Test/Silence buttonBattery replacementUnder normal conditions, the LED normally flashes every 8 sec to indicate normal opera

Seite 28 - RADION PIR

Test/Silence buttonRefer to the RADION smoke detector illustration for location of the Test/Silence button.– Testing. Press the Test/Silence button fo

Seite 29 - Figure 7.1: Walk test

123Figure 9.3: Remove the detector cap1 ᅳ Optical base2 ᅳ Optical chamber3 ᅳ Alarm cap5. Use compressed air or a soft-bristled brush to remove dust an

Seite 30 - RADION PIR C

RADION contact SMThe RFDW-SM is a standard surface-mount wireless transmitter device used for monitoringdoors and windows.Features include:– An intern

Seite 31 - Figure 8.1: Walk test

– When installing the magnet, verify that the notches in the magnet base, line up with thenotches in the transmitter base, otherwise the magnet and tr

Seite 32 - RADION smoke

RADION contact RMThe RFDW-RM is a recessed-mounted wireless transmitter device used for monitoring doorsand windows. Features include:– Self-contained

Seite 33

How to read the Graphical Magnet Distances tableContained in the recessed door/window contact Installation Guide is a graphical table alongwith the X

Seite 34 - Table 9.3: LED

9RADION smoke 329.1 Battery replacement 339.2 Smoke test 339.3 Sensitivity test 339.4 Test/Silence button 349.5 LED 349.6 Clean the detector and repla

Seite 35 - RADION smoke

RADION specialtyRFBT is a designed transmitter (bill trap) specifically used in financial or retail environments.It transmits a silent, wireless alarm

Seite 36 - RADION contact SM

bank vault at the close of each business day. In this scenario, the bank vault system is alwaysarmed, and the bill trap remains in a non-faulted condi

Seite 37

RADION universal transmitterThe RFUN is a wireless transmitter used for monitoring doors, windows, and other dry contactdevices.Features include:– A c

Seite 38 - RADION contact RM

4 ᅳ 2.2 k Ω tamper EOL5 ᅳ Input disabled – no contact, 2.2 k Ω EOL Installation considerationsYou have a variety of installation options to consider w

Seite 39

Callout ᅳ Description1 ᅳ No jumper disables the internal reed switch2 ᅳ Jumper on enables the internal reed switch 44 en | RADION universal transmitte

Seite 40 - RADION specialty

RADION keyfobRADION keyfobs (two button and four button) are personal transmitters carried by the userthat allow the user to remotely arm or disarm a

Seite 41 - Installation consideration

– Panic alarm– LED indicator– Programmable option buttonsFigure 14.1: Keyfob buttons and LED1 ᅳ Arm button2 ᅳ LED3 ᅳ Disarm button4 ᅳ Programmable but

Seite 42 - RADION universal transmitter

Figure 14.2: Keyfob buttons and LED1 ᅳ Arm button2 ᅳ LED3 ᅳ Disarm buttonRADION receiver OP RADION keyfob | en 47Bosch Security Systems, Inc Reference

Seite 43 - Reed switch settings

RADION panicThe RFPB-SB/RFPB-TB is a transmitter that sends a panic alarm signal to the security systemwhen one (single button panic), or both panic b

Seite 44 - Callout ᅳ Description

LED RedFrequency 433.42 MHzTable 15.1: SpecificationsNotice!Please note, the battery does not come installed. Verify that the correct battery as defin

Seite 45 - RADION keyfob

IntroductionThis document contains the basic information that a trained installer needs to install theRADION system. It supplements the documents list

Seite 46 - RADION keyfob TB

AppendicesIcons and symbolsUse the table below for descriptions of the icons and symbols used in the reference guide.Description Icon/symbolNot pet fr

Seite 47 - 3 ᅳ Disarm button

Electrostatic discharge symbolSymbol against disposing batteries intothe garbageHumidity rangeTemperature rangeFrequency rangeDuration of timeQuestion

Seite 48 - RADION panic

Battery-related information.Perform a walk testWalk test has concludedDevice has wall tamper detection.52 en | Appendices RADION receiver OP02.2014 |

Seite 50 - Appendices

Bosch Security Systems, Inc.130 Perinton ParkwayFairport, NY 14450USAwww.boschsecurity.com© Bosch Security Systems, Inc., 2014

Seite 51

6 en | Introduction RADION receiver OP02.2014 | 01 | F.01U.261.835 Reference Guide Bosch Security Systems, Inc

Seite 52 - Walk test has concluded

General installationPhases of installationThe installation of the RADION system is achieved by following the sequential process asdefined in this chap

Seite 53

Unpacking informationWhen unpacking the receiver, repeater, or bill trap device, it is important to remove thecardboard insert as illustrated below;Fi

Seite 54

To ensure proper operation of the RADION devices, test the basic functionality of the devicelocally. Depending on the RADION device to be tested, perf

Kommentare zu diesen Handbüchern