Conettix Plug-in Communicator InterfaceB450 en Installation and Operation Guide

Seite 2

InstallationPerform the following steps to install the B450.Notice!Remove all power (AC and Battery) before making any connections. Failure to do so m

Seite 3 - Table of contents

12Figure 4.2: Inserting the communication module into the B450Callout ᅳ Description1 ᅳ B44x Plug-in Communicator module (available separately)2 ᅳ B450

Seite 4 - 4 en

Figure 4.3: Mounting the module to the exterior wall of the enclosureCallout ᅳ Description1 ᅳ B4502 ᅳ Enclosure (outside wall shown)3 ᅳ Mounting screw

Seite 5 - Introduction

1. Place the magnetic antenna on top of the enclosure, or vertically on another metalsurface.Notice!If you are experiencing a weak signal, place the a

Seite 6 - 6 en

Notice!Use either the terminal strip wiring or interconnect cable to wire to the control panel. Do notuse both. When connecting multiple modules, you

Seite 7 - System overview

Wire to an SDI control panel RYGBRYGB3RYGB11242Commercial Protected-Premises Control PanelD9412GV3 Control Panel is UL Listed For Central Station, Rem

Seite 8 - Bus address settings

Wire to an option bus control panelRun the wiring connections from the module to the data bus terminals on the compatiblecontrol panel.Notice!When wir

Seite 9 - Bus address label

ConfigurationNotice!Power up the system prior to the configuration workflows described in this chapter. You can configure the B450 using one of the me

Seite 10 - Installation

Figure 5.1: B450 settings shown as B42x in RPS with a GV4 control panel at v1.0018 en | ConfigurationConettix Plug-in CommunicatorInterface2013.09 | 0

Seite 11 - Installation

Figure 5.2: B450 settings shown as B42x in RPS with a GV4 control panel at v2.00 Reference the table below for parameters configured by RPS. Conettix

Seite 13 - Wire to the control panel

Parameter Value DescriptionTamper (for GV4 ([v1.0.x orhigher] control panels)0 = Disabled1 = EnabledWhen enabled, allows tamperand tamper restorecondi

Seite 14 - Wire to an SDI2 control panel

Table 5.1: B450 networking parameters configurable in RPS Notice!If you are using a GV4 version 1.00 control panel, select “B420 Ethernet Communicato

Seite 15 - Wire to an SDI control panel

Figure 5.4: B450 status as shown as Ethernet Communicator in RPS Diagnostics with GV4 version 2.00 Use USB to configure the B450You can use a USB conn

Seite 16 - 16 en

9. To the right of the B450, click on the language link (for example, en).The File Download dialog box opens.10. Click Save to save the file to the ta

Seite 17 - Configuration

Install a communication programTo use USB connection from a computer to the B450 to configure the B450, you must use acommunication program.– Windows

Seite 18 - 18 en

Figure 5.7: Tera Term Pro version 4.77 window shownLog into the USB interfaceNotice!To allow for USB configuration, address switch must be set to 0. P

Seite 19 - Configuration

Figure 5.8: B450 USB login window5. Enter the password to log on. The default password is B450.The user interface allows three attempts to enter the p

Seite 20 - 20 en

USB Main menu1234Figure 5.9: USB Main MenuCallout Description1 Installed device2 Current device status3 Current access level4 Main menu options The US

Seite 21 - Configuration

AdvancedConfigurationChangePasscodeStatus(Starts withBasic Status)Reset Status1Signal Strength342Main MenuReset toFactory Defaults 5ExitMain MenuBasic

Seite 22 - Use USB to configure the B450

Option PresstoSelectDescription1. Status (Startswith BasicStatus)1 To access and view the link, modem, and bus statusFor additional menu descriptions,

Seite 23 - Configuration

Table of contents1Safety 42Introduction 52.1 About documentation 52.2 Bosch Security Systems, Inc. product manufacturing dates 52.3 Installation workf

Seite 24 - 24 en

Option PresstoSelectDescription3. Reset Status 3 The status displays show several items that are counts of activities, such as UDPpackets transmitted.

Seite 25 - Log into the USB interface

Option PresstoSelectDescription1. ModifyDiagnosticSettings1 The Diagnostic logging is intended for use only under Bosch direction. Diagnosticsettings

Seite 26 - 26 en

ID Parameter Values Description20 SMS Configuration 0 = Disabled1 = EnabledAllows the B450 to be configured via SMSconfiguration.65 IPv4 DNS Server IP

Seite 27 - USB menu structure

Notice!To allow the receipt of SMS data, the bus address switch must be set at position 0. Refer tothe tables in this section for LED activity.If the

Seite 28 - USB menu

ID Description Advanced parameters65= Primary DNS server address (IPv4 address format)66= Alternate DNS server address (IPv4 address format)67= Panel

Seite 29 - Configuration

Send the Configuration SMS1. Send the configuration SMS to the B44x module’s phone number. The transmission mighttake several minutes. Because the bu

Seite 30 - 30 en

Figure 5.11: B450 USB login window4. Select option 7 Firmware Update and press [Enter].5. From the Tera Term main menu, select File>Transfer>XMO

Seite 31 - Configuration

Figure 5.13: File navigation7. Click Open to start the firmware update. The Tera Term: XMODEM Send dialog box opensand indicates the update process.Co

Seite 32 - Use SMS to configure the B450

Figure 5.14: Tera Term XMODEM Send dialog box8. When the file transfer completes, the Tera Term: XMODEM Send dialog box closesautomatically. Within th

Seite 33 - Configuration

Maintenance and troubleshootingLED status indicatorsThe B450 includes the following on-board LEDs to assist with troubleshooting:– Heartbeat (system s

Seite 34 - %2;19=1;!

SafetyESD PrecautionPlease note that while the B450 comes in a plastic case, and is protected from ESD, the plug-in cellular communicator (B44x) does

Seite 35 - Firmware Update page

Trouble condition LEDsCondition B450 Heartbeat B450 Transmit(TX)B450 Receive(RX)Plug-in modulestatusModule tamper Not indicatedPlug-in modulemissingOn

Seite 36

SMS configuring LEDsCondition B450HeartbeatB450 Transmit(TX)B450 Receive(RX)Plug-in modulestatusInvalid SMS messagereceived1 sec flash The Transmit (T

Seite 37 - Configuration

Example 1 - High Security ApplicationPolling times are typically less than 20 min. Path integrity is critical, and short interruptions innetwork servi

Seite 38 - 38 en

Control panel programming using cellularFor more information regarding proper planning and installation parameters related to VPNsetup for control pan

Seite 39 - LED status indicators

Specifictions and certificationsTechnical specificationEnvironmental considerationsRelative humidity Up to 93% non-condensingTemperature (operating) 0

Seite 40

Compatible control panelsB5512/B4512/B3512D9412GV4/D7412GV4 v2.00D9412GV4/D7412GV4 v1.00.0xxD9412GV3/D7412GV3/D7212GV3FPD-7024 (v1.03+)CertificationsR

Seite 43 - F01U273558)

Bosch Security Systems, Inc.130 Perinton ParkwayFairport, NY 14450USAwww.boschsecurity.com© Bosch Security Systems, Inc., 2013

Seite 44 - Technical specification

IntroductionAbout documentationCopyrightThis document is the intellectual property of Bosch Security Systems, Inc. and is protected bycopyright. All r

Seite 45 - Certifications

Install a communication program (if required) (Refer to Install a communication program,page 24) Configure the communication module (non SDI2 control

Seite 46

System overviewRefer to the graphic below for the complete B450 system configuration.12789 5634B450 system connections overviewCallout ᅳ DescriptionCa

Seite 47

B450 module overview18629103754TXRXFigure 3.1: B450 Plug-in Communicator InterfaceCallout ᅳ Description1 ᅳ Tamper switch connector2 ᅳ Bus address swit

Seite 48

Bus address labelUse the bus address label to select the desired setting on the bus address switch, dependingon your control panel.PANEL ADDRESSESTXRX