6 of 6
COMMON MISTAKES
1. Using the incorrect Elan DB-9 to RJ-45 adapter to connect to the security panel hardware. Use the
HA-CB-328, which provides the required NULL modem conversion.
2. Incorrect Dip Switch settings on the DX-4010 serial interface module. When connecting to a g!
Controller Pins 1-4 must be ON, 5-8 must be off to set address 80. (During programming, the
dipswitches may be altered to 1-3 ON, 4-8 OFF).
3. Attempting to control a panel with latched reset. There is a latch hook to hold RESET on the Bosch
panel (located above the SDI wiring terminals) that must be latched to program in RPS. The Bosch
will not communicate with g! while Reset is latched. The Panel will sound at a consistent interval if
Reset is latched.
4. Incorrect PIN settings between Bosch and g!--g! must have PIN settings that match the Bosch
programming. Ex. Master (mode 1) does not require a PIN, Auto Arm should be set to Yes in g!
Configurator. Perimeter (mode 3) requires 4 digits, set Auto Arm NO and Number of Keys “4 Keys” in
g! Configurator.
5. Incorrect Panel Programming. See the Panel programming steps above for special considerations
when programming a Bosch panel for integration with g!.
Kommentare zu diesen Handbüchern