EN
|
42
Bosch Security Systems | 02 April 2004
LTC 8850 | Instruction Manual | Allegiant Server
ALARM CUSTOM TABLE
Alarm Custom Table
Figure 80 Alarm Type Configuration with Context Menu
The Custom Alarm tab will be displayed when one or
more alarm types have been set to Custom in the
alarm type table. Custom alarms are used to perform
user-defined operations instead of activating alarm
video.
Figure 81 Alarm Custom Configuration Table
A Custom alarm is not associated with any camera
number or remote function. Once the selected alarms
are defined in the Alarm Type for a custom response,
the actual user-defined actions may be entered in the
Custom menu according to the desired function.
Check the Action Enabled box to enable the alarm's
custom action. Then enter a CCL command in the
Activation Action and/or Deactivation Action
columns. (See the separate CCL manual for a list of
available CCL commands.) When a custom alarm is
activated, it will execute the CCL command listed
under Activation Action. When the alarm input is
deactivated, it will execute the Deactivation Action.
These actions are performed instead of the usual
alarm-response behavior. The combined activation and
deactivation CCL commands listed for an alarm may
total no more than 22 characters. In addition to CCL
commands, references to the user defined custom
scripts can be entered. Refer to the Command Script
Table section for more information.
3.2.6.4 User Table
The User table is used to define the identity and
activity limits of the users.
Figure 82 User Configuration Table
User ID Number
The User ID number is any three digit number from 1
to 999. A maximum number of users that can have
access to the system depends on model type.
No duplicate user numbers are permitted. If desired,
users can be grouped together by number groups. For
example, all first shift employees could have user
numbers starting with 1 (1xx), all second shift
employees could have user numbers starting with 2,
(2xx), etc.
System
Model
LTC
8100
LTC
8200
LTC
8300
LTC
8500
LTC
8600
LTC
8800
LTC
8900
Max Users 32 32 32 32 32 32 128
Kommentare zu diesen Handbüchern