DCN Next Generation Open Interface Release 2.4 Microphone Management
en | 90
Bosch Communications Systems | 2007 February | SRS_MMINF | Du020903
Error codes returned
MM_E_NOERROR
MM_E_OPEN_CLOSE_FAILED
Related functions
MM_C_START_MM
3.2.3 MM_C_START_MON_MM
Purpose
Function to start the monitoring behavior of the Microphone Management application. It is not
allowed/possible to control settings of Microphone Management.
Parameter structure for the function
The function has no additional parameters.
Response structure from the function
The function returns the following structure:
WORD wNrOfInstances
where:
wNrOfInstances The value of the update use count for the MM application at the
end of the function handling. It contains the number of times a
remote PC has connected over the same communication
medium. E.g. the first time the MM_C_START_MON_MM
function is called, it contains the value 1.
Error codes returned
MM_E_NOERROR
Related functions
MM_C_STOP_MM
MM_C_STOP_MON_MM
3.2.4 MM_C_STOP_MON_MM
Purpose
Function to stop monitoring the behavior of the Microphone Management application.
Parameter structure for the function
The function has no additional parameters.
Response structure from the function
The function returns the same response structure as the remote function
MM_C_START_MON_MM (section 3.2.3)
Error codes returned
MM_E_NOERROR
Related functions
MM_C_START_MM
MM_C_START_MON_MM
3.2.5 MM_C_SET_MIC_OPER_MODE
Purpose
This function allows the remote controller to change the microphone operation-mode.
Parameter structure for the function
The function requires the following structure as parameter:
WORD wOperationMode;
where:
wOperationMode The operation mode of the MM application which is one of the
Kommentare zu diesen Handbüchern