29
en
Simple troubleshooting
Problem Cause Solution
The personally selected
volume is not reached.
Coee dispensing slows to a
trickle or stops completely.
Coee is ground too nely.
Preground coee is too ne.
Adjust the grinding level
to a coarser setting. Use a
coarser ground coee.
Heavy build-up of limescale in
the appliance.
Descale the appliance
according to the instructions,
see the section “Service
programs”.
The brewing unit is soiled. Clean brewing unit, see
chapter “Cleaning the
brewing unit”.
Hot water milky or tastes
of coee.
Milk tube has not been
removed.
Remove the milk tube from
the milk container.
Milk or coee residue in the
beverage outlet.
Clean the beverage outlet.
Coee has no “crema”. Unsuitable type of coee. Use a type of coee with a
higher proportion of robusta
beans.
The beans are no longer fresh. Use fresh beans.
The grinding level is not
suitable for the beans.
Adjust the grinding unit to a
ner setting.
Coee is too “acidic”. The grinding level is too
coarse. Preground coee is
too coarse.
Adjust the grinding unit to
a ner setting. Use a ner
ground coee.
Unsuitable type of coee. Change the type of coee.
Coee is too “bitter”. Coee is ground too nely.
Preground coee is too ne.
Adjust the grinding level
to a coarser setting. Use a
coarser ground coee.
Unsuitable type of coee. Change the type of coee.
Coee tastes burnt. The brewing temperature is
too high.
Reduce the temperature,
see the section “Drink
adjustment”.
Coee is ground too nely.
Preground coee is too ne.
Adjust the grinding level
to a coarser setting. Use a
coarser ground coee.
Unsuitable type of coee. Change the type of coee.
Coee is too “weak”. Coee strength selected is
too weak.
Raise the strength of the
coee, see the section “Drink
adjustment”.
Ground coee jammed in the
coee drawer.
Remove the ground coee
drawer, clean and dry
thoroughly.