RE 64 557/02.07 | Type 4/6THF5
– Mounting flange area: Flatness = 0.5 mm
– Screw head dimensions = Ø 10 mm
– Dimensions of shims (large M6) placed underneath the screw heads = Ø 18 mm
– Tightening torque for the flange fixing screws = Max. 10 Nm
– Tightening torque for the pipe connections = Max. 30 Nm
Installation hole 4 THF 5
Installation hole 6 THF 5
– Ø 108 = nominal diameter / fixing via 4 screws and 4 shims
– 72 mm = between axis
– Fixing via 4 screws and 4 shims
– Limit the control pilot circuit pressure to 35 bars maximum for a good resistance of the electrical detents.
– Do not direct the jet of a pressure washing unit directly at the unit.
– The electrical cable must be kept free of any mechanical forces.
– During operation protection via the rubber boot must be ensured.
– Only use the unit with its original grip and lever.
– Ensure that the inertia data of the original grip are not exceeded.
– Replace worn push buttons, so that the integrity of the EC2000 grip is ensured.
– Only one function control must be allocated to an E-contact.
– The circuit functions are to be so designed that uncontrolled machine movements caused by the application are prevented and
that it is possible to switch from one function to another.
– Take into account all of the application limits, particularly those application limits stated within this catalogue sheet.
– Preparation for assembly and testing on the machine: The various checks must include all the functions of the pilot control
device.
Application guidelines (these guidelines are not intended to be considered as complete)
Safety guidelines (these guidelines are not intended to be considered as complete)