DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 67
Bosch Security Systems | 8/04 | 4998153891C
4.4.4 Keypads
Wired Keypads 1 to 8 are fixed at Data Bus Addresses 1 to 8. See “Keypad Addressing” in the DS7200V2
Installer’s Guide (P/N: 4998153893). All keypads (and other Data Bus devices) are fully supervised. Supervision
reports, such as missing and tamper, follow the System Status Report routing.
Keypad # Options
• Address:
− Keypad 1: 0678
− Keypad 2: 0680
− Keypad 3: 0682
− Keypad 4: 0684
− Keypad 5: 0686
− Keypad 6: 0688
− Keypad 7: 0690
− Keypad 8: 0692
• Default: 7
• Selections: 0 to 15
Enter This Data Digit to Select Options
Keypad Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
No Keypad Options
•
Beep Keypad on System Trouble
• • • • • • • •
Enable Exit Tone
• • • • • • • •
Enable Area Display (DS7446KP Keypad)
• • • • • • • •
Don’t Show Zone Status on Keypads
• • • • • • • •
• Beep Keypad on System Trouble: If enabled, this option sounds a tone at the keypad when a System
Trouble occurs.
• Enable Exit Tone: If enabled, this option sounds the Exit Delay tone at this keypad when Exit Delay is
active.
• Enable Area Display (DS7446KP Keypad): If this option is enabled, the DS7446KP Keypad shows the
current state of each area using its four Area icons.
Table 11: DS7446KP Keypad Icon Functions
Function Condition
Icon flashes fast Area is in alarm
Icon is On Steady Area is in armed, but not in alarm
Icon flashes slow Trouble condition exists, or zone is bypassed in area
Icon is Off Area is disarmed, no alarm/trouble conditions exist, no zones are bypassed
If the “Enable Area Display” option is disabled, the DS7446KP Keypad displays the area to which it is
currently assigned if it is not in its home area. If the keypad moved to another area, the icon for the new area
lights steady. For example, if the keypad moved ([#][5][0]) to Area 1, no area icons are lit. If it moved to Area
2, the Area 2 icon turns on.