Bosch ISW-BIT1-HAX WLSN INSTALLATION Spezifikationen Seite 17

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 60
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 16
wLSN | Reference Guide | 2.0 General Installation
Bosch Security Systems, Inc. | 3/07 | F01U009440-01 17
Mode 3
Select Mode 3 by pressing [3].
MOD
y
3: SExxdBmx
NxxdBmx
SNRy
The Mode 3 display shows the signal to noise ratio (SNR) at the
location you are testing. Signal refers to the signal strength of the
incoming message from the wLSN Hub to the Installation Tool.
Noise refers to the ambient noise level that exists at the location.
The signal must be greater than the noise (S>N). The higher the
SNR is, the stronger the location’s signal is at that location. Refer
to Table 4.
In the Mode 3 display “SNR yy” refers to the signal to
noise ratio in dB and “x” is the RFSS value in dBm.
Dashes, appearing on both the S and N lines, indicate
unacceptable signal strength.