IP Camera 200 Series Installation | en 19
Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.5 | 2011.01
3.5 I/O connector
Figure 3.4 I/O connector pins
– Cut back 5 mm (0.2 in) of insulation.
– Relay output switching capability: Max. voltage 24 VAC or
24 VDC. Max. 1 A continuous, 12 VA.
– Relay in: Short or +5 VDC activation.
– Alarm input configurable as active low or active high.
Function Wire Color
Relay out AWG20 Grey
AWG20 Red
Alarm input AWG30 Orange
AWG30 Brown
5 mm
(0.2 in)
In: AWG30
Out: AWG20