NurseCall N46 Wall Transmitter Operation | en 23
Bosch Security Systems User Manual 970.030 | v1.1 | 2009.09
7 Operation
7.1 Description of the six different states
During operation, the NurseCall N46 Wall Transmitter can be set to one of six following states:
Each state is indicated by the signal lamp and by a special position of the output relays.
It is possible to configure the NurseCall N46 Wall Transmitter in order that:
– the Call for Assistance can be triggered only if the Care Personnel is present.
– the device does not manage the Staff Presence. This mode makes sense only if the
output relays are not provided or not used.
The transition to a specific condition depends on the device configuration, of its actual condi-
tion and of the action completed; as shown on the charts in the following chapters.
State Description
Stand-by No call is being processed.
Alarm without staff presence The patient has triggered a Call for Help but the Care
Personnel has not yet responded.
Alarm with staff presence The Care Personnel has responded after a Call for Help.
Assistance without staff presence A Call for Assistance has been triggered without the
presence of the Care Personnel.
Assistance with staff presence A Call for Assistance has been triggered in the presence
of the Care Personnel.
Staff Presence without alarm The Care Personnel has responded without a previous
call from the patient.
i
NOTICE!
When the NurseCall N46 Wall Transmitter is powered by an external power supply, the signal
lamps follow the state of the corresponding relay outputs.