– no parity
– 1 stop bit
– hardware flow control
Click OK.
7. Press F1 for displaying the system options menu of the device.
8. Enter 1 to set the IP address and the subnet mask as required.
9. Leave the default settings for the ports:
– port1: 4201
– port2: 4200
Adding the ATM/POS bridge to Bosch VMS
1. Connect the device to your Bosch VMS network.
2. Start Configuration Client.
3. Click
Devices, expand the Logical Tree, expand , right-click , click
Add Bosch ATM/POS-Bridge.
The Add Bosch ATM/POS-Bridge dialog box is displayed.
4. Type a name as desired and type the settings that you configured earlier.
5. Click the Inputs tab and select the required inputs.
6. Click
to save the settings.
7. Click Events.
8. Expand , expand POS Bridge Input, click Data Input.
9. In the Trigger Alarm list, select Always to ensure that this event always triggers an alarm.
If you want the event trigger an alarm only during a certain time span, select a schedule.
10. Click to save the settings.
11. Click Alarms.
12. Configure the desired alarm settings for this event.
13. Click to save the settings and click to activate the configuration.
14. Perform a test to ensure that the alarm is working as desired.
Adding a Bosch Allegiant input alarm
After a Bosch Allegiant device is added to Bosch VMS, you add Allegiant alarm inputs.
1. On the Device Tree, click the Allegiant device entry.
2. Click the Inputs tab and click Add Input.
3. Add the desired input alarms.
4. Click Events.
5. In the Event Tree, expand Allegiant Devices, expand Allegiant Input, and click Input
Closed or Input Opened (depends on your application).