To un-assign a decoder, right-click the analog monitor image and click Clear Monitor.
Advanced Configuration page
Main window >
Devices > Expand > > Advanced Configuration tab
Allows you to perform the following tasks:
Configure the logical number of a decoder or decoder channel.
Enable quad view for decoders that support quad view
Configure the OSD.
Notice!
We do not recommend configuring quad view for H.264 cameras.
Note the following hints on switching the decoder between quad view and single view in the
Operator Client:
The user can manually switch the decoder back to single view when it is configured as
quad view.
When the decoder is switched to single view or to quad view and a sequence is just
running, only the last video stream remains visible.
When the user switches to quad view, the last cameras that have been displayed on
Image pane 2-4 are reconnected.
This is also valid for trunk lines. There is only one limitation: If the matrix camera cannot
be reconnected, this is ignored without an error message. A black Image pane is visible.
When switching to single view, all trunk lines that are displayed on Image pane 2-4 are
disconnected. Only the camera number is stored for a later switch to quad view.
Decoder Name
Displays the display name of the decoder.
Network Address
Displays the IP address of the decoder.
Logical Number
Enter the logical number of the decoder. If you enter an already used number, a message is
displayed.
Quad
Displays the position of the decoder on the quad view. 1 is left upper corner, 4 is right lower
corner.
Quad View
Select the check box to enable quad view for this decoder. On the Settings page, the
corresponding analog monitor image displays the quad view. Logical numbers are created
automatically. If you want the Operator Client user to be able to switch between quad view
and single view, then check Quad View. If you clear Quad View, the Operator Client user
cannot switch.
AMG
Displays the analog monitor group that the decoder in this row is assigned to.
Initial Camera
Click to select the camera that is displayed initially on the monitor after having started the
Operator Client. The logical number of the initial camera is displayed as the white number on
the monitor image in the Settings page.
23.15.2
Bosch Video Management System Devices page | en 159
Bosch Sicherheitssysteme GmbH Configuration Manual 2013.07 | V1 | Configuration Client
Seitenansicht 158