Caution!
If you change the number of LUNs, the entire iSCSI system is reorganized and any sequences
saved on the system are lost.
Therefore, before making changes, check the recordings and back up any important
sequences.
Capacity for new LUNs [GB]
This option is only displayed for E-Series.
As 256 is the maximum number of LUNs of a storage array, the LUN size should not be set to a
too small value (otherwise no more LUNs can be created in the future, if an additional shelf is
installed).
Target spare disks
Number of spare disks the user wants the system to have.
Actual spare disks
Number of spare disks which are currently in the system. This number can differ from the
number above, e.g. if the storage system is reconfigured manually or if disks are broken.
Initialization status (%)
Additional information is displayed during initialization. When initialization is complete
(100%), you will also have the opportunity to delete all LUNs again.
Note: On FAS storage systems, it can take several hours before LUNs are fully deleted. During
that time, the total capacity of newly created LUNs can be reduced. You can only create new
LUNs with full capacity after the old LUNs have been completely deleted.
RAID-DP (reliability focused)
Activate this option if you do not wish to use the specified RAID type RAID-4, but would prefer
to use the more reliable RAID type RAID DP.
RAID 6 (reliability focused)
Activate this option if you do not wish to use the specified RAID type RAID-5, but would prefer
to use the more reliable RAID type RAID 6.
Clear
Clears the configuration, i.e. deleting all LUNs.
Defaults
Sets the storage system back to its factory default. Additionally to clear the storage system
name and all iSCSI IP addresses are deleted. Only management addresses and the
configuration password are retained.
Serial number
The serial number needed for support cases. It is only correct if the controller is not moved to
a different shelf.
Delete all LUNs
As already stated above the user should wait some hours before he creates new LUNs.
Additional information
Additional information is displayed here, for example information that the storage system is
not configured correctly and that therefore no setup is possible.
Load Balancing page
Main window >
Devices > Expand > Expand > Expand > >
Load Balancing tab
23.27.7
176 en | Devices page Bosch Video Management System
2013.07 | V1 | Configuration Client Configuration Manual Bosch Sicherheitssysteme GmbH
Seitenansicht 175
1 2 ... 171 172 173 174 175 176 177 178 179 180 181 ... 259 260

Kommentare zu diesen Handbüchern

Keine Kommentare