Notice!
UL requires any device powered from a power output to be supervised.
Total available power
The control panel produces up to 800 mA of combined power at 12.0 VDC nominal to power
peripheral devices. The outputs listed below and OUTPUT A share the available power.
AUX terminal (auxiliary power)
Powers devices requiring continuous power (for example, motion detectors).
R/PWR terminal and power output of the interconnect connector (SDI2 power)
Power SDI2 devices such as a B208 Octo-input Module, a B308 Octo-output Module, or B920/
B930 keypads.
Plug-in module connector
Connect plug-in modules such as the B440 Conettix Plug-in Cellular Communicator.
OUTPUT A
Output A can be configured as a dry contact (contact rating is 3 Amps), switched common
(sink current), or a powered output. As a powered output, it can provide alarm power or
switched auxiliary power. The default configuration for Output A makes it a powered output
providing alarm power. Use OUTPUT PARAMETERS in RPS to configure programmable
outputs.
Refer to Configure OUTPUT A using the jumper, page 9.
Open collector outputs
OUTPUT B and C
Outputs B and C are open collector outputs that can sink up to 50 mA of power (+12 VDC),
when activated.
As an example, the figure below shows using Outputs B and C to trigger the relays of a D134
Dual Relay Module.
5.1.2
5.2
Control Panels Introduction | en 19
UL Installation Instructions 2013.01 | 04 | F01U265448