5.4.5 Emergency Override/Free Exit
There is a special case where both the DR2 and DR1
signals are interpreted differently to the way
described for door monitoring. The DR2 signal is
used to monitor an emergency switch, such as a
break glass, and DR1 provides a Free Exit report.
Note:
When this feature is used there is no door alarm
monitoring. For details on how to enable this feature,
refer to Readykey K2200 Series Controllers User Guide
(Bosch P/N: 47491, PAC P/N: 17376).
Figure 21: Emergency Override / Free Exit Wiring
-VE
GND
DR1
DR2
N/O
N/C
Door ContactBreak Glass
Reader
Door
Controller
N/C
Request to Exit
Special Case for Emergency Override and Free Exit
Emergency Override
When connected as shown in Figure 21, operating
the break glass will open the door and produce an
Emergency Override On report. When the
switch is restored an Emergency Override Off
report is produced and the door will be locked again.
THIS FEATURE SHOULD NOT BE
FITTED AS THE SOLE MEANS OF
ESCAPE.
Free Exit
When this option is set, pressing the Request to Exit
switch will produce a Free Exit report. The door
contact will allow door left open warnings to be
produced.
A normally closed switch may be used to operate as
a request to exit switch, in addition to having a door
contact switch in series (see Figure 21). An additional
special lock mode (Option 8) needs to be set, in
addition to option 2, to allow this feature (see Table
24).
Note 1:
Using this arrangement, the lock will operate whenever
DR1 is opened - this means that care should be taken
that the door contact cannot be broken from the secure
side of the door.
Note 2:
As free exit was designed to work with a door contact
or pushbar the door contact “bounce time” is applied
and the response will be slow if used like an Request to
Exit switch (1.25 seconds).