K2200 Series | Installation Guide | 6.0 Configuration and Testing EN | 46
Bosch Security Systems | 7/03 | 17375 1.3 / 46513C
Note:
It is recommended that the dial-back times are set using
Readykey for Windows.
5. Telephone number 1 for dial-back.
Press [ENT] to save, press [NXT] to go on
6. Telephone number 2 for dial-back.
Press [ENT] to save, press [NXT] to go on..
7. For this feature to operate, P must be specified
for Setup - Remote Acknowledge, Dialback and
Comms Protection.
PROTECT COMMS N
This feature allows dial-up communications to be
established only when the master keycode sent
by the CNC matches the master keycode stored
in the door controller.
Type [N] to allow the next dial-up to be
accepted. The next master key that is sent by the
CNC will be accepted by the door controller and
stored. All future dial-ups must have a match
between this code and the one sent by the CNC.
Press [ENT] to save, press [NXT] to go on.
8. Up to 16 Hayes-compatible modem control
characters can be entered here.
You should only need to use these if the modem
connected requires more than the standard
programming provided by default.
Do not put
any characters in here unless instructed to do
so by Bosch Technical Support.
To enter characters not provided on the keypad,
you can use the [•] key, followed by the
following letters:
Table 22: Key Combinations to obtain keys
not on keypad
[•] key +
Result
A &
P%
B \
D$
Q ?
E=
S *
End of setup. Press [ESC] to return to CMD
prompt.
6.1.8 Event Mode
Five options are provided which can prevent certain
types of transaction being sent by the door controller
to the administration system. This can be useful in a
busy system to speed up the communication of more
important events, or on dial-up systems to keep
connect times short.
1. From the CMD prompt, type [T] then press
[ENT].
CMD_T
2. This allows programming of Request to
Exit, Request for Entry event filtering.
Type Y and [ENT] to ignore these events.
FRGT RTR N
Press [ENT] to save, press [NXT] go on.
3. This allows programming of Free Exit event
filtering. Type Y and [ENT] to ignore these
events.
FRGT FREE EXIT N
Press [ENT] to save, press [NXT] go on.
4. This allows programming of filtering of events
generated by time profiles. These are all
"automatic/auto" events, e.g. Automatic Lock
and Auto Zone Disable. Type [Y] and [ENT] to
ignore these events.
FRGT TIME EVNT N
Press [ENT] to save, press [NXT] go on.
5. This allows programming of "allowed" or
positive events - Access Authorized,
Entry Authorized, Exit out of Hours
and Exit Authorized. Type Y and [ENT] to
ignore these events.
FRGT POS TRANS N
Press [ENT] to save, press [NXT] to go on.
6. This allows programming of all events where
access is denied (negative events - No Access
: 'reason' events. .
Type [Y] and [ENT] to ignore these events.
FRGT NEG TRANS N
Press [ENT] to save, press [NXT] go on.
7. This allows programming of positive transaction
dial-back for door controller 1 (i.e. the door
controller connected directly to the modem).
DIAL D/C1 DR----
Type the door number (reader channel number)
for which you wish dial-back to be initiated in
the case of a positive event occurring followed by
[ENT].