Security Escort | Installation and Setup Guide | 2.0
E
q
ui
p
ment Estimation
EN | 15
Bosch Security Systems | 1/09 | 33831E
1.8.6 SE112
Description
Custom Test Receiver with LCD display.
1.8.7 CTS1-70 Enclosure Cover/Wall
Tamper
Description
The CTS1-70 can be installed in AE1
and AE3 Enclosures for use as a cover
tamper switch, a wall tamper switch or
both (two required). The CTS1-70 is
intended for connection to normally
closed tamper or supervised circuits,
and operates as a normally closed
device when the plunger is depressed.
Specifications
Contacts are rated 0.3 A, 100 VDC,
maximum.
2.0 Equipment Estimation
A Security Escort system installation
consists of three major steps.
1. The pre-bid equipment estimation
2. The pre-construction coverage
verification survey
3. The post construction setup
The Security Escort Receivers work
effectively in a wide variety of
installations and can be placed with
confidence provided these installation
requirements are met. Therefore, at
the pre-bid stage, it is acceptable to
estimate the required equipment. To
ensure proper coverage after proposal
acceptance, potential receiver
locations can be verified using a
standard receiver in test mode or the
portable test receiver before
construction begins.
2.1 Location Accuracy
The Security Escort system provides
quick response to a duress call by
dispatching a responding individual to
an area without adding additional
delay to their response to that duress
call.
The Security Escort system uses radio
frequency (RF) for alarm
transmissions. This is significant
because it prevents normal
construction from blocking the signal
and helps to eliminate dead spots
where the alarm cannot be heard. The
fact that RF energy passes through
normal construction prevents Security
Escort from locating an alarm with
100% certainty to a specific side of a
wall. Alarms originating at or near
building walls are typically indicated
within 7.5 m (25 ft.) of the actual
location; however, there may be times
when the computed location may appear
to be on the other side of the wall.
The Security Escort system was
designed to provide a computed alarm
location typically within 7.5 m
(25 ft.) of the actual location when
indoors and a computed alarm location
typically within 15 m (50 ft.) of the
actual location outdoors. Any
deviation from the following
installation guidelines degrades the
computed location accuracy. Use the
following installation guidelines, to
achieve these results.