Security Escort | Installation and Setup Guide |4.0 System
Power-u
p
and Debu
g
EN | 38
Bosch Security Systems | 1/09 | 33831E
4.0 System Power-up and
Debug
4.1 Initial System
Configuration
Refer to the section Initial System
Configuration in the document titled
Security Escort Technical Reference
Manual (P/N: 38947) to configure the
software. Transfer the information
from the installation data sheets to
the Transponder Database and assign
the Comm ports to the SE485 bus or
ProxLink Radio. Make sure that the
databases are backed-up using the
Utilities MenuBackup selection.
Back-up the databases whenever they
change, and keep multiple copies.
4.2 Powering Up the System for
the First Time
After the system is configured, the
system may be powered up. If the
system uses multiple transponders, it
is easier and more effective to power
up the transponders one at a time. By
doing this troubleshooting time can be
significantly reduced, especially if
there is a wiring problem in the SE485
bus between transponders.
Note:
It is very important that twisted
pair wiring is used for the SE485
bus. The Tx+ and Tx- wires must be
twisted together and the Rx+ and
Rx- wires must be twisted together.
1. Turn on the power switch on the
first transponder. In the Security
Escort central console software
select Setup Menu Transponder
Current Status. The screen shown in
Figure 18 appears: