Function
Parameter
No.
Description
Blast mode
34
Sets the mode for the Blast feature
Manual – The conveyor will output a percentage of maximum
as set in P39.
Auto – The conveyor will output the rate set in P38.
Note: The blast mode will be the same as the control mode
set in P20.
Spinner stop or
no stop
35
Sets the action of the spinner.
Never – Spinner will always turn when the dial is set.
Speed – Spinner will start and stop with ground speed.
Pause – Spinner will only stop when the pause button is
pressed.
Speed & Pause – Spinner will stop with ground speed
and the pause button.
Conv. Pulses
per rev.
36
This value is the number of pulses generated by the conve
yor
motor feedback sensor with every rotation.
CLP blast
38
Determines the conveyor output in LB’s/mile or kg/km while
the conveyor is in closed loop mode. Do not exceed maximum
application rate setting. (Parameter 9)
Blast mode
rate
39
The number shown
here is the percentage of maximum
conveyor output speed at which the system will operate while
in manual Blast mode.
Calibrating the
ground speed
44
Ground speed calibration
see
calibration procedure on page
13.
Ground Speed
pulses per Km
or Mile
45
Th
e number of Pulses per Kilometer or Mile produced by the
ground speed sensor. This parameter is calculated by the
controller during the calibration process and requires no
adjustment. (Please see page 14 for further discussion.)
Over
-
speed
alarm
46
A warn
ing buzzer will sound when the vehicle speed exceeds
set value in MPH or KM/H. (Set the parameter to 0 to turn
function off.)
System Units
57
This parameter selects either metric (0) or imperial (1)
operation.
System
language
58
This parameter selects th
e language; (0) for English and (1)
for French.
Resetting all
parameters
59
Resets all parameters to factory default settings
.