5 Programming and Setting Up the System
5.1 Quick Set-up Guide
• Insert programming key and turn to activate program mode
• Set the units of measure – either imperial or metric using P57
• Set the desired material application rates using P1 through 9
• Set the desired liquid rates using P70-79
• Set the desired operating control mode of the solid using P20 – toggle the
toggle the toggle the
toggle the
power on and off to accept the control mode change
power on and off to accept the control mode changepower on and off to accept the control mode change
power on and off to accept the control mode change
• Set the desired operating control mode of the liquid using P25 – toggle the
toggle the toggle the
toggle the
power on and off to accept the control mode change
power on and off to accept the control mode changepower on and off to accept the control mode change
power on and off to accept the control mode change
• Set the desired material output while in the BLAST mode using P38 or 39
• Set the desired “Spinner Stop” mode using P35
5.2 Nulling of the Solenoids
5.2.1
5.2.1 5.2.1
5.2.1
Nulling the Solenoids and Engine RPM
Nulling the Solenoids and Engine RPMNulling the Solenoids and Engine RPM
Nulling the Solenoids and Engine RPM
Note: Depending on hydraulic pump size, it may be necessary to increase the engine
RPM to approximately 1500 RPM during the nulling procedure, in order to ensure
sufficient oil flow.
If the conveyor is in closed loop mode and equipped with a feedback sensor, use of
the auto-nulling feature in P21 is desired.
• Set the controller to P21
P21P21
P21
• Press the Conveyor Dial to activate this parameter
• Press the UPPER SELECT KEY and the auto null sequence will begin
• When finished (approximately 90 seconds) press blast to exit and store this
parameter
5.2.2
5.2.2 5.2.2
5.2.2
Manually Nulling the Solenoid and Setting the Minimum Conveyor Speed
Manually Nulling the Solenoid and Setting the Minimum Conveyor SpeedManually Nulling the Solenoid and Setting the Minimum Conveyor Speed
Manually Nulling the Solenoid and Setting the Minimum Conveyor Speed
• Set the controller to P81
P81P81
P81
• Press the Conveyor Dial to activate this parameter
• Press the UPPER SELECT KEY until the conveyor starts to turn
• Press the LOWER SELECT KEY in small increments until the conveyor stops
• Press the Conveyor Dial to lock in the setting
5.2.
5.2.5.2.
5.2.3
33
3
Manu
ManuManu
Manually Nulling the Solenoid and Setting the Maximum Conveyor Speed
ally Nulling the Solenoid and Setting the Maximum Conveyor Speedally Nulling the Solenoid and Setting the Maximum Conveyor Speed
ally Nulling the Solenoid and Setting the Maximum Conveyor Speed
• Set the controller to P82
P82P82
P82
• Press the Conveyor Dial to activate this parameter
• Press the UPPER or the LOWER SELECT KEY until the conveyor is running at the
maximum hydraulic motor speed. Observe RPM in closed loop mode displayed
on the screen