liquid rates
Nine liquid rates can be configured.
per P57
P57P57
P57.
..
.) The rate programmed under Parameter 70 will be
the rate under position 1 of the liquid dial in operation mode.
Parameter 79 is position 9 of the liquid dial.
Conveyor start
up
Conveyor Forward Gain provides an additional ou
conveyor on startup. This feature overcomes initial inertia and
friction at startup, allowing for an even distribution of
material from a stopped position.
minimum
conveyor speed
Nulling of the conveyor solenoid to set the minim
controller output amperage required to start the conveyor.
Required to get a smooth startup of the conveyor. Page 12.
maximum
conveyor speed
Nulling of the conveyor solenoid to set the maximum
controller output amperage required for maximum conveyor
speed. Required to reduce over-amperage to the coil to
extend its life.
minimum
spinner speed
Nulling of the spinner solenoid to set the minimum controller
output amperage required to start the spinner. Required to
get a smooth startup of the spinner.
maximum
spinner speed
Nulling of the spinner solenoid to set the maximum controller
output amperage required for maximum spinner speed.
Required to reduce the over applied amperage to the coil to
extend its life.
minimum liquid
speed
uid solenoid to set the minimum
output amperage required to start the liquid pump. Required
to get a smooth startup.
maximum
liquid speed
Nulling of the spinner solenoid to se
output amperage required for maximum spinner speed.
Required to reduce the over applied amperage to the coil to
extend its life.