Bosch 430 Spezifikationen Seite 11

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 17
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 10
11/17
Bosch Rexroth Canada ı 16.10.2008 ı Revision 2.2
Function
Parameter
No.
Description
Setting the
liquid rates
70 to 79
Nine liquid rates can be configured.
(L/Tonne or Gal
/Ton as
per P57
P57P57
P57.
..
.) The rate programmed under Parameter 70 will be
the rate under position 1 of the liquid dial in operation mode.
Parameter 79 is position 9 of the liquid dial.
Enhancing
Conveyor start
up
80
Conveyor Forward Gain provides an additional ou
tput to the
conveyor on startup. This feature overcomes initial inertia and
friction at startup, allowing for an even distribution of
material from a stopped position.
Setting the
minimum
conveyor speed
81
Nulling of the conveyor solenoid to set the minim
um
controller output amperage required to start the conveyor.
Required to get a smooth startup of the conveyor. Page 12.
Setting the
maximum
conveyor speed
82
Nulling of the conveyor solenoid to set the maximum
controller output amperage required for maximum conveyor
speed. Required to reduce over-amperage to the coil to
extend its life.
Setting the
minimum
spinner speed
83
Nulling of the spinner solenoid to set the minimum controller
output amperage required to start the spinner. Required to
get a smooth startup of the spinner.
Setting the
maximum
spinner speed
84
Nulling of the spinner solenoid to set the maximum controller
output amperage required for maximum spinner speed.
Required to reduce the over applied amperage to the coil to
extend its life.
S
etting the
minimum liquid
speed
85
Nulling of the liq
uid solenoid to set the minimum
controller
output amperage required to start the liquid pump. Required
to get a smooth startup.
Setting the
maximum
liquid speed
8
6
Nulling of the spinner solenoid to se
t the maximum controller
output amperage required for maximum spinner speed.
Required to reduce the over applied amperage to the coil to
extend its life.
Seitenansicht 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 17

Kommentare zu diesen Handbüchern

Keine Kommentare