Bosch Alarm Panel Interface Manual
Revision 1.4
1 Introduction
This manual describes registration, setup, and operation of the System Galaxy Alarm Panel Interface to
the Bosch Alarm Panel.
This manual also includes specific information about alarm panel settings that are required in order to
connect with System Galaxy 7.2 or higher (covered in section 2.1). This manual does not replace or
supersede the manufacturer’s manual. Installer must refer to manufacturer’s documents for complete
information pertaining to the Alarm Panel or Alarm System (i.e. installation, wiring, programming, use).
1.1 System Galaxy supports the following alarm panel features:
SG receives real-time status messages from the alarm panel when the panel is on-line with SG
SG is able to monitor alarm conditions and points can be linked to SG Alarm features
SG can send typical system commands to the alarm panel (i.e. Arm/Disarm, Bypass/Un-Bypass,
etc. depending on operator privileges and panel programming)
SG supports the Always Armed -24 Hour Point and Bypass Allowed features. Note that 24-hr
Points cannot be bypassed even if the Bypass Allowed option is checked. And points cannot be
bypassed if Bypass option is not checked or if the operator privileges do not allow the option.
SG can link alarm points to Galaxy Alarm Events, DVR Cameras and CCTV Systems.
SG can send (add) and retrieve (get next available/unused) user codes and assign user codes to
multiple cardholders. Ability to ac32cess this type of programming depends on operator
privileges.
SG can send text messages to the keypad. The static message displays until replaced with next
message
SG can retrieve “point text” from the alarm panel.
1.2 Requirements: System Galaxy interface with alarm panel
System Galaxy 7.02 (or higher) interfaces with the Bosch 9000/7000 series alarm panels.
The alarm panel should be installed and configured before configuring System Galaxy. The installer
should install and configure the Bosh Alarm Panel according to the manufacturer’s documentation.
Section 2.1 of this manual includes known settings for connecting to the alarm panel.
System Galaxy must be registered for Alarm Panel interface before it can be configured for the alarm
panel. Once registration is complete, the Alarm Panel, Areas, Points and User Codes can be added
to System Galaxy.
The GCS Alarm Panel Service must be running in order to connect and receive/send events. The
AP Service runs as a true background service and independent of user logins.
The GCS DBWriter Service must be running for the Alarm Panel service to connect to the panel
The GCS ClientGW Service must be running for human-readable events to display at the monitor;
also this service must be running for operator to send commands to the panel.
Page 5 of 37