Bosch CC880/LP880, SC8016 Spezifikationen Seite 22

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 21
CC880/LP880, SC8016 | Quick Reference Guide | 5. Programming Parameters EN | 22
Bosch Security Systems | 6/04 | 4998152461B
5.24.2 Zone Allocations for Area 2
Location
700 to 707
Location Default
Zone 1 LED – Area 2 Codepad 700 0
Zone 2 LED – Area 2 Codepad 701 0
Zone 3 LED – Area 2 Codepad 702 0
Zone 4 LED – Area 2 Codepad 703 0
Zone 5 LED – Area 2 Codepad 704 0
Zone 6 LED – Area 2 Codepad 705 0
Zone 7 LED – Area 2 Codepad 706 0
Zone 8 LED – Area 2 Codepad 707 0
5.24.3 Zone Allocations for Area 3
Location
708 to 715
Location Default
Zone 1 LED – Area 3 Codepad 708 0
Zone 2 LED – Area 3 Codepad 709 0
Zone 3 LED – Area 3 Codepad 710 0
Zone 4 LED – Area 3 Codepad 711 0
Zone 5 LED – Area 3 Codepad 712 0
Zone 6 LED – Area 3 Codepad 713 0
Zone 7 LED – Area 3 Codepad 714 0
Zone 8 LED – Area 3 Codepad 715 0
5.24.4 Zone Allocations for Area 4
Location
716 to 723
Location Default
Zone 1 LED – Area 4 Codepad 716 0
Zone 2 LED – Area 4 Codepad 717 0
Zone 3 LED – Area 4 Codepad 718 0
Zone 4 LED – Area 4 Codepad 719 0
Zone 5 LED – Area 4 Codepad 720 0
Zone 6 LED – Area 4 Codepad 721 0
Zone 7 LED – Area 4 Codepad 722 0
Zone 8 LED – Area 4 Codepad 723 0
5.25 User Code Area Assignment
Location
724 to 755
User Code 1 to 32
0 User code not assigned
1 User code assigned to Area 1
2 User code assigned to Area 2
4 User code assigned to Area 3
8 User code assigned to Area 4
5.26 Serial Printer Baud Rate
Location
756
1 300 baud
2 600 baud
3 1200 baud
4 2400 baud
5.27 Dialler Lockout Count (V1.40+)
Location
757
Default
0
0 No lockout
1 to 15 Number of times dialler operates until
lockout
5.28 Safecom Programming
5.28.1 Safecom – RF Fail (V2.00+)
Location
760 to 763
Location Default
Contact ID Event Code
Hundreds 760 3
Tens 761 5
Units 762 3
Dialler Channel (Point ID = 30
Hexadecimal/48 decimal)
763 1
5.28.2 Safecom – Telco Fail (V2.00+)
Location
764 to 767
Location Default
Contact ID Event Code
Hundreds 764 3
Tens 765 5
Units 766 1
Dialler Channel (Point ID = 31
Hex./49 decimal)
767 1
5.28.3 Safecom – RF Jamming (V2.00+)
Location
768 to 771
Location Default
Contact ID Event Code
Hundreds 768 3
Tens 769 4
Units 770 4
Dailler Channel (Point ID = 32
Hex./50 decimal)
771 1
5.28.4 Safecom – RF Jamming Delay (V2.00+)
Location
772
Default
0
0 No RF jamming delay
1 to 15 RF jamming delay in minutes
5.28.5 Safecom RF Supervision Time (V2.02+)
Location
773
Default
10
0 No RF supervision time
1 to 15 RF supervision time in minutes
5.28.6 Safecom Reporting Options (V2.00+)
Location
896
1 Safecom communication reporting disabled
2 Arming from ST1000 base allowed
4 Disarming from ST100 base allowed
8 Reserved
5.28.7 Safecom Interface Serial Number
The eight-digit serial number of the Safecom
interface board can be read in the locations below.
Location
920 to 927
Default
0
Seitenansicht 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 31 32