CC880/LP880, SC8016 | Quick Reference Guide | 7. Wiring Diagrams EN | 29
Bosch Security Systems | 6/04 | 4998152461B
Figure 8: Component Overlay 2
1
4
2
3
5
6
11
7
8
10
14
15
17
9
12
16
13
1 = Termination for phone line
2 = Line fault module (note polarity)
3 = Receive/Transmit
4 = Socket for telecom lead connection
5 = Voice module, modem module, phone amplifier,
or direct link cable (note polarity)
6 = Zone termination strip
7 = Default switch
8 = Relay contact
9 = Battery consumption LED (when illuminated,
indicates power is being drawn from the
battery)
10 = Remove link for dry contact
11 = Output termination strip
12 = Programming key or programmer plugs in here
13 = Battery charge globe remains fully illuminated
until the battery is 100% charged
14 = Battery input
15 = Plug pack input (Bosch Security Systems
TF008)
16 = 3 A battery fuse
17 = 1 A accessory fuse (for external equipment)