EN
|
17
Bosch Security Systems | December 8, 2004
LTC 8100, LTC 8200, LTC 8300 Series | Instruction Manual | Installation Procedure
6.3.1 Mounting Ear Removal
If the LTC 8300 Series is to be used as a desk top
unit, remove each mounting ear by removing the
screw holding the mounting ear to the enclosure
chassis (see Figure 3).
Figure 3 Cover and Rack Brackets Removal
6.3.2 Video Termination Selections
The video input termination DIP switches are located
toward the rear of the circuit board. Note that the
Factory Default Settings are all ON (input terminated
with 75Ω). Only those switches associated with looping
video inputs need to be changed to OFF (unterminated).
6.3.3 CPU Module Selections
To access the circuit board, remove the cover and lid as
described in the COVER REMOVAL Section. The batteries
and the two 8-position system configuration DIP switches
(S0201 and S0202) near the front of the unit will now be
visible. Change only the desired CPU DIP switches
based on the features described in the
FACTORY DEFAULT
SETTINGS
Section of this manual.
6.3.4 Battery Replacement
If the batteries have reached the end of their useful life,
the Time and Date portion of on-screen display will
begin to alternate with an indication of ?? ?? ??. The
LED on the front panel of the unit will also light,
indicating a low battery condition. Access the circuit
board as described in the INTERNAL SELECTIONS
Section above, then follow the instructions found in the
MAINTENANCE INFORMATION Section of this manual
for replacement procedures.
6.4 Termination Practices
Video from every camera should be terminated with a
75Ω resistance. Each video line should be terminated
exactly once. If video from a camera is going to several
devices, only the last device on the video line should be
terminated.
6.4.1 Video Terminations
The main circuit board has DIP switches to select the
termination of each video line. To terminate an input line,
ensure that the appropriate DIP switch on the video
module is ON (Factory Default Setting). If non-
terminated operation is required for looping purposes,
turn the switch OFF. See the TABLE below to determine
the DIP switch numbers that correspond to video input.
Video Switch Switch Systems
Inputs No.
1-4 S0801 1-4 LTC 8100, LTC 8200, LTC 8300
5-8 S0802 1-4 LTC 8100, LTC 8200, LTC 8300
9-12 S0801 5-8 LTC 8200, LTC 8300
13-16 S0802 5-8 LTC 8200, LTC 8300
17-20 S0803 1-4 LTC 8300
21-24 S0804 1-4 LTC 8300
25-28 S0803 5-8 LTC 8300
29-32 S0804 5-8 LTC 8300
Video Input Termination Switches
If looping video inputs are desired, the LTC 8200 and the
LTC 8300 Series require an optional LTC 8808/00 patch
panel (for the LTC 8100 Series, the looping BNCs are
included on the unit). A single LTC 8808/00 provides
looping capability for all 16 (LTC 8200) or 32 (LTC 8300)
video inputs. If necessary, refer to the Section on
LOOPING VIDEO CONNECTIONS below.
Just like camera inputs, monitor outputs on the Allegiant
system are designed to be terminated. Each monitor
output expects to be connected to a 75Ω load. This is the
load typically provided by a monitor. If a monitor output
line is looped through several monitors or other
equipment, ensure that only the last unit on the line is
terminated.
CAUTION: Lithium Battery
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type
recommended by the manufacturer. Dispose of used
batteries according to the battery manufacturer’s
instructions.