18
Bosch Security Systems | December 8, 2004
LTC 8100, LTC 8200, LTC 8300 Series | Instruction Manual | Installation Procedure
6.5 Looping Video Connections
The Allegiant Series has outputs available for video
input looping connections. Looping connections for
LTC 8200 and LTC 8300 require the optional
LTC 8808/00 Video Interconnect (patch) Panel. The
patch panel provides 32 BNCs for video connections.
Patch panels are connected to the rear of the main bay
via supplied ribbon cables. Each cable can carry video
for up to 16 cameras. For LTC 8300 Series systems,
2 cables can be attached to the patch panel to support
up to 32 cameras. Each ribbon cable should be attached
to the appropriate VIDEO connector on the rear of the
main bay.
LT C 8808/00 Typical Use
Figure 4 Video Interconnect Panel
6.6 Keyboard Hookup
Connect a maximum of 4 (LTC 8300 or LTC 8200
Series) or 2 (LTC 8100 Series) system keyboards to
any of the keyboard ports (modular phone type jacks)
provided on the rear of the main bay. Be sure to
connect a keyboard to at least port #1.
NOTE: The LTC 8555 Series RS-232 type keyboards
are not connected to the standard keyboard ports.
The keyboards connect to the Console port, or to a
LTC 8712 Series Port Expander. Note that when
LTC 8555 RS-232 type keyboards are connected to the
system, the corresponding standard keyboard ports
are automatically disabled.
Each keyboard is supplied with a 3 m (10 ft) cable for
local hookups. Allegiant systems can provide power
to keyboards up to 30 m (100 ft) away via the optional
LTC 8558/00 hookup cable. For distances of up to
1.5 km (5000 ft), the optional LTC 8557 Series hookup
kit is required. This product is supplied with a remote
power pack, and requires user-supplied shielded twisted
pair (Belden 9841 or equivalent) for communication.
6.7 Biphase Control Code Output
Connections
Allegiant systems provide separate outputs (16 for
LTC 8300, 12 for LTC 8200, 8 for LTC 8100 Series) for
driving remote receiver/drivers, switcher/followers, and
satellite systems. Either star or daisy chain wiring
configurations may be used.
Connect shielded twisted pair cable between the camera
site receiver/driver locations (or other accessory device)
and any of the outputs provided on the Allegiant’s rear
panel. Use the straight slot side of the supplied offset
screwdriver to tighten the terminal block screws.
Maximum transmission distance is 1.5 km (5000 ft) using
1 mm
2
(18 AWG) shielded twisted pair (Belden 8760 or
equivalent). Contact removable screw terminal blocks are
provided with up to 4 separate connection groups per
block. Each group provides three connections; +, , and S
(Shield). Do not mix connections between groups, i.e.
connecting one wire of the cable to the + of one group and
another wire of the same cable to the of another group.
Each output is rated to handle up to 8 receiver/drivers, as
in a daisy chain configuration, to a maximum of 1.5 km
(5000 ft). Select and maintain a wire color convention to
avoid confusion at the various camera sites.
Example: White to +, Black to , and Shield to S.
The CODE OUT LED located on the Allegiant front
panel will flash when the joystick, a lens control, or a
video switching action is activated. The CODE OUT
LED also flashes occasionally when system status
information is being generated by the system.
6.8 External Alarm Connections
The LTC 8100, LTC 8200, and LTC 8300 Series contain
integral alarm input and output connections. These alarm
inputs provide automatic display of video under alarm
conditions. The units accept up to 32 (LTC 8300),
16 (LTC 8200), 8 (LTC 8100) contact closures or logic
level inputs from remote sensing devices (door contacts,
PIRs, etc.). The alarm inputs are designed to generate
alarm conditions upon closure of the external contacts
(normally open contacts). The units also provide
6 (LTC 8300), 5 (LTC 8200), or 2 (LTC 8100) relay
closure outputs upon alarm conditions.
Alarm input connections are made to 12 contact
removable screw terminal blocks located on the rear panel.
Each terminal block provides 8 alarm input connections.
Lower
LTC 8809/00 Cable
Upper
LTC 8809/00 Cable
LTC 8300
Seitenansicht 17