Code To Isolate
The method will restrict only those user codes that have the priority level ‘Code To Isolate’
set to be able to isolate zones. Therefore, if any user code has this priority level set, the
method of standard isolating will not function. Your security company can only program the
priority level for each user code.
How To Isolate A Zone
1. Press the * button followed by your user code and the * button again to enter the
isolating mode (eg. *2580*). Three beeps will be heard and the STAY indicator will
flash.
2. Enter the zone number (1 – 16) that you wish to select to isolate followed by the *
button. (eg. 1* = Zone 1, 16* = Zone 16 etc).
As you select each zone to be isolated, you will notice that the corresponding zone
indicator will begin to flash. If you selected an incorrect zone to be isolated, enter the
incorrect zone number again followed by the * button.
Repeat Step 2 if more than one zone is required to be isolated until all zones that are
required to be isolated have been selected.
3. Press the # button after you have selected all zones to be isolated.
Two beeps will be heard and the system will return to the disarmed state.
Fault Analysis Mode
If a system fault should occur, the FAULT or MAINS indicator will flash and the codepad
will beep once ever minute.
If the AC mains supply has failed, the MAINS indicator will flash until the AC mains supply
has restored. Pressing the # button once will acknowledge the fault and stop the codepad
from beeping once every minute.
How To Determine The Type Of System Fault
To determine which system fault has occurred, enter fault analysis mode by following the
steps outlined below.
1. Press and hold button 5 until two beeps are heard.
The FAULT indicator will remain steady and the STAY and AWAY indicators will
flash in unison with each other.
A zone indicator will display to indicate the type of fault that has occurred (eg. Zone 1
= Battery Fail). Refer to Table 7: Fault Indicators on page 17 for the list of different
faults that may occur.
2. To exit and return to the disarmed state, press the # button. The FAULT indicator will
remain displayed and the codepad will cease its once a minute beep.
16
!"#$%&"'()* Operators Manual
ISSUE160.DOC Electronics Design and Manufacturing Pty Limited