DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 33
Bosch Security Systems | 1/05| 4998154963B
Step 2: Assigning a Zone Function to the Zone
In this step, a zone function is assigned to the zone.
5.9.2 Zone Programming: Assigning a Zone Function to the Zone
In zone programming, each zone is defined according to its assigned input (single or multiple zone input, or a
DS7465i) and its zone function (1-30) or output function (1-24). Use the first column of Table 20 to list how you
programmed Addresses 0001 through 0030.
See the DX7400XiV4 Wireless Reference Guide (P/N: 4998154790) for additional information.
The DS7465i occupies two zones. The odd-numbered zone of the zone pair is the input zone. The
even-numbered zone of the zone pair is the output relay. The output follows an output function.
• Addresses: 0031 to 0278
• Data Digits:
• See the first column of Table 20 for Zone Functions; see Table 21 for defaults.
• Selections: 00 (zone disabled), or 01 to 30. See the first column of Table 20 for the pre-defined zone functions.
Table 21: Address 0031 to 0278 Zone
Programming Default Values
Zone Number Address Zone Function
Default
1 0031 01
2 0032 02
3 0033 03
4 0034 04
5 0035 05
6 0036 06
7 0037 07
8 0038 08
9 to 248 0039 to 0278 00
NOTE: Address = Zone Number + 30