DS7400XiV4-EXP | Reference Guide | 5.0 Programming the Control Panel EN | 59
Bosch Security Systems | 1/05| 4998154963B
5.9.24 RS-232 Interface Control Programming
RS-232 Interface Control Programming allows you to enable or disable the interface and to select which history
events are sent to the printer as they occur. Selecting No Events causes the history to only print on command.
To print the History Buffer starting from the most recent event, enter the Master Code followed by [#][0][8]. To
stop printing, enter Master Code [#][0][8] again.
• Address: 4019
• Data Digit:
• Data Digit 1: ____ (see Table 83; default = 0)
• Data Digit 2: ____ (see Table 84; default = 7)
• Selections: 0 or 1 for Data Digit 1; 0 to 7 for Data Digit 2.
Table 83: Address 4019, Data Digit 1
Select Option Value
DS7412 Disabled
0
DS7412 Enabled 1
Table 84: Address 4019, Data Digit 2
Selections for Data Digit 2
Select Options 0 1 2 3 4 5 6 7
No Events
•
Alarms, Troubles, and Restorals
•
•
•
•
Opens and Closes
• •
• •
All Other Events
• • • •