Tamper
Each DX2010 module has an onboard tamper and one tamper input, not belonging to zone
inputs.
When the tamper event of DX2010 module occurs, the tamper report is sent with the module
address.
Address Setting
Notice!
When data bus address is changed, the module needs to be re-powered to make the new
address effective.
Each DX2010 module connected to the alarm control panel must have its own data bus
address. Refer to following Table for information.
Module Data Bus Address
DX2010 module 1 (zones 17 - 24) 103
DX2010 module 2 (zones 25 - 32) 104
DX2010 module 3 (zones 33 - 40) 105
DX2010 module 4 (zones 41 - 48) 106
DX2010 module 5 (zones 49 - 56) 107
DX2010 module 6 (zones 57 - 64) 108
Table 5.4: DX2010 Address Settings
For Address DIP switch settings, refer to the followingTable.
DIP Switch
S1 S2 S3 S4 S5 S6
Data Bus Address 32 16 8 4 2 1
103 Off Off Off Off On Off
104 Off Off Off Off On On
105 Off Off Off On Off Off
106 Off Off Off On Off On
107 Off Off Off On On Off
108 Off Off Off On On On
Table 5.5: DX2010 DIP Switch Settings
5.2.3
5.2.4
AMAX panel 4000 / AMAX panel 4000
EN
Optional Modules and Peripheral Devices | en 15
Bosch Sicherheitsysteme GmbH Installation Guide 2013.07 | 03 | F.01U.267.112