2 - Interior Instant
The interior instant zone will perform as below:
1. Disarm:
same as the Instant Zone disarm status
2. AWAY Arm:
same as the Instant Zone AWAY Arm status
3. STAY Arm:
This Zone will be Ignored and performed as disarm. Refer to Section Keypad
Indicators, page 20 to see how the zone is displayed during exit time.
When Zone is triggered, not bypassed and system is forced to arm, a Zone fault
report is send.
When System is disarmed and zone is not restored before, a Zone fault restore
report is sent
3 - Delay
The delay zone will perform as below:
1. DISARM: Same as Instant zone disarm status
2. AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Entry time starts - no Alarm / no report
Disarming during entry time - no Alarm / no report
Zone triggered - during exit time - no Alarm / no report
Zone triggered - during entry time - no Alarm / no report
Zone triggered - entry time is expired - Alarm / report
(report is delayed for 30sec, when system is disarmed before, no report)
3. STAY ARM: Same as AWAY ARM performance.
First delay zone will start the entry time; all other delay zones will follow.
When System is disarmed and zone is not restored before, a Zone restore report is
sent.
4 - Interior Delay
The Interior delay zone will perform as below:
1. Disarm: same as the Instant Zone disarm status
2. AWAY Arm: same as the Delay Zone AWAY Arm status
3. STAY Arm:
This Zone will be Ignored and performed as disarm.
Refer to Section Keypad Indicators, page 20 to see how the zone is displayed during
exit time.
5 - Follower
The follower zone will perform as below:
1. Disarm:
same as the Instant Zone disarm status
2. AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
Zone triggered - during exit time - no Alarm / no report
Zone triggered - during entry time - no Alarm / no report
The remaining Delay Time is handed over from the Delay Zone to the Follower Zone.
The follower zone will performance as the same as a delay zone.
AMAX panel 4000 / AMAX panel 4000
EN
Settings | en 49
Bosch Sicherheitsysteme GmbH Installation Guide 2013.07 | 03 | F.01U.267.112