05 Follower
06 Interior Follower
07 24-Hour
08 Key-Switch Toggle
09 Key Switch on/off
10 24 Hour Panic
11 24 Hour Fire
12 24 Hour Fire With Verification
13 Tamper
14 Bolt Contact
15 External Fault
16 Delay Exit
17 Interior Delay Exit
18 Technical Alarm
19 Reset
20 Instant Without Reset
21 Reserved
0
If a zone is not used, program the zone type location to 0. An EOL resistor is not required if
this zone type is not used. This zone type never activates the sirens or the dialer.
1 - Instant
The instant zone will perform as below:
1. Disarm:
– Zone normal - no Alarm / no report
– Zone triggered - no Alarm / no report
2. AWAY Arm:
– Zone normal - no Alarm / no report
– Zone triggered - Alarm / report
– (Zone triggered during exit time no Alarm / no report)
– (Zone triggered during entry time Alarm / report is delayed for 30sec or entry time is
expired, when system is disarmed before, no report)
3. STAY Arm:
– Zone normal - no Alarm / no report
– Zone triggered - Alarm / report
– (Zone triggered during exit time no Alarm / no report)
– (Zone triggered during entry time Alarm / report is delayed for 30sec or entry time is
expired, when system is disarmed before, no report) When Zone is triggered, not
bypassed and system is forced to arm, a Zone fault report is sent.
– When System is disarmed and zone is not restored before, a Zone fault restore
report is sent.
48