Y
G
B
R
AUX 2+
AUX 2-
AUX 1-
AUX 1+
R
B
G
Y
DX3010
Yellow
Green
Black (-)
Red (+)
Alarm Control Panel
External Power Supply
(+)
(-)
Figure 5.8: Connecting DX3010 to the Control Panel with External Power Supply
Notice!
When the external power supply is used, the black wire (-) is not allowed to be grounded.
Address Setting
Notice!
When data bus address is changed, the module needs to be re-powered to make the new
address effective.
Each DX3010 module connected to the alarm control panel must have its own data bus
address. For details refer to the Table below.
Module Data Bus Address
DX3010 module 1 (Output 5 ~ 12) 150
DX3010 module 2 (Output 13 ~ 20) 151
Table 5.7: DX3010 Address Settings
For Address DIP switch settings, refer to the Table below.
DIP Switch S1 S2 S3 S4 S5 S6
Data Bus Address 1 2 4 8 16 Mode
5.3.3