AC power fault AC power fuse is burnt. Check if the 18V of the
transformer is correctly
wired and replace the
fuse.
Over current protection of the
auxiliary power
Abnormal wiring of the
12V auxiliary power
The auxiliary power
exceeds the power
supply upper limit of
2000mA for the control
panel.
Reconnect the auxiliary
power.
Use external power
supply for perimeter
devices.
The auxiliary power cannot be
recovered after short circuit.
AC power and battery
fail.
Power up AC power and
battery again.
Failure of battery is still
displayed after the battery is
replaced
The battery might be
tested 4 hours after the
system is armed each
time.
The voltage of the
battery is lower than
12V.
The fault will be
automatically cleared
when the system is reset
or the battery is re-
tested.
Charge the new battery
for a period of time until
the voltage reaches 12V
or above.
Not entering programming
mode after power up.
The system is in alarm
state.
The system is in arming
state.
Reset the alarm.
Disarm the system and
keep it in the disarming
status.
The red LED on the main
board goes off
Abnormal AC power and
backup battery.
The main board fails.
Check AC power and
backup battery.
Replace the main board
The system does not dial
when the alarm presents.
Relevant receiver
parameters are not set.
Correctly set the
telephone number, set
transmission format to
CID and set zone alarm
to corresponding paths.
Remote telephone arming
fails.
The remote telephone
arming is disabled (the
address 0144 is set to
0).
There are multiple areas
in the system.
Program the address
0144 to a number from 1
to 15.
The telephone arming is
available when the
system has area 1 only.
RPS cannot perform remote
programming and control.
Both addresss 0144 and
0145 are set to 0.
Program the address
0144 to a number from 1
to 15. Program the
address 0145 to 1.