If the output is activated by Entry Timer 1, Entry Timer 2, or Entry Guard Timer for STAY Mode,
the output is reset when the Entry Time or Entry Guard Time expires or the system is
disarmed.
If a zone programmed for Day Alarm is activated when the system is disarmed and Day Alarm
is turned on in the area to which this zone is allocated, the output is reset when the zone is
resealed or Day Alarm is turned off in the area to which this zone is allocated or the system is
armed. You can turn Day Alarm on and off by holding down [4] or selected from the menu on
KP.
0,13 Exit Warning + Entry Warning + Day Alarm Resetting
This output operates when the system is armed, regardless of whether zones are sealed or
unsealed, until Exit Time expires or the system is disarmed.
The output operates again during Entry Time and is reset when Entry Time expires or the
system is disarmed. The output also operates during the Entry Guard Timer for STAY Mode
time and is reset when the Entry Guard Time expires or the system is disarmed.
If a zone programmed for day alarm is activated when the system is disarmed or Day Alarm is
turned off in the area to which this zone is allocated or the system is armed, the output is
reset when the zone is resealed or Day Alarm is turned off in the area to which this zone is
allocated or the system is armed. You can turn Day Alarm on and off by holding down [4] or
selected from the menu on KP.
0,14 Day Alarm Resetting
This output operates when a zone programmed for Day Alarm is activated while the system is
disarmed and Day Alarm is turned on in the area to which this zone is allocated. The output is
reset when the Day Alarm zone is resealed or Day Alarm is turned off in the area to which this
zone is allocated or the system is armed. You can turn Day Alarm on and off by holding down
[4] or selected from the menu on KP.
0,15 Day Alarm Latching
This output operates when a zone programmed for Day Alarm is activated while the system is
disarmed and Day Alarm is turned on in area to which the zone is allocated. The output is
reset by pressing [AWAY]. You can turn Day Alarm on and off by holding down [4] or selected
from the menu on KP.
If the control panel is partitioned, you can reset only this output on the area codepad to which
the zone is allocated.
1,0 Day Alarm Enabled
This output operates when Day Alarm is enabled in any one used area. The output is reset
when Day Alarm is turned off in all used areas.
You can turn Day Alarm on and off by holding down [4] or selected from the menu on KP.
Three beeps indicate that Day Alarm is turned on, two beeps indicate that Day Alarm is turned
off.
1,1 Telephone Line Fail
This output operates when the built-in telephone line fault module detects that the telephone
line is disconnected longer than 40 sec. The output is reset when the telephone line is
restored continuously for 40 sec. This output does not operate unless Option 1 in Location
176 is selected or the function "Telephone Line Fault Indicator” (Menu 3-5-4) is enabled.
1,2 Kiss-off Received
This output operates after the control panel successfully transmitted to the receiving party, or
else the output is reset.
1,3 AUX Power Supply Fail
This output operates when the 12V SDI2 BUS devices power supply or 12V zone or output AUX
power supply fails. The output is reset when all fault AUX power supply above is reset..
1,4 AC Fail
Control Panel
Programmable Outputs | en 133
Installation Guide 2014.07 | 00n | F01U298026