Notice!
Setting or not setting a callback number does not affect Answer Machine Bypass connection.
Network Connection with IP
Use the IP connect feature to program a Solution 2000/3000 control panel using a portable
computer. Telephone lines and modems are not required necessary.
To program the network connection with IP:
1. Connect a B426 network module to the control panel using the SDI2 bus.
2. Program location 81 as 1, but do not config network module 1. It is not necessary to
program Location 180. The IP connect feature ignores this option.
3. From the B426 screen, set Web and Automation security as Enable.
4. From the A-Link Plus Customer Information screen, enter the full control panel IP address
and control panel port number for the B426.
Network Connection with Domain Name
Use the Domain Name connect feature as another method to program the Solution 2000/3000
control panel using a portable computer.
To program the network connection with Domain Name:
1. Connect the B426 network module to the control panel using the SDI2 bus.
2. Program location 81 as 1, but do not config network module 1.
3. From the B426 screen, set Web and Automation security as Enable.
From the A-Link Plus Customer Information screen, enter the full control panel IP address, the
domain name, for example: Test123.BOSCH.com, and the full control panel port number for
the B426.
Options
Options for
location 180
Description
1 Upload/download allowed
2 Callback phone number required for upload/download
4 Exit from upload/download connection on alarm
8 Reserved
When programming the locations, select options from the table above. Select options in any
combination by programming a single value. Calculate this value by adding the option bit
numbers together. For example, to program options 1 and 4, set the option as 5. To program
only option 1, set the option as 1.
1 Upload/download allowed
Select this option to use the A-Link plus Software to program the control panel remotely. The
control panel does not respond to the A-Link plus Software if this option is not selected.
2 Callback phone number required for upload/download
If this option is selected and a callback telephone number is programmed, the remote
programming computer must be connected to the telephone line programmed in the callback
telephone number in locations 159 to 174.