This output operates when the AC MAINS fails. The output is reset when the AC MAINS is
restored. This output operates regardless of whether Option 2 in Location 494 is selected or
on TEXT codepad the Menu 341 "Ignore AC Fail" is enabled.
1,5 Low Battery
This output operates when a Dynamic Battery Test detects the battery failed or the battery
voltage is below 11.0 VDC. The Dynamic Battery Test is performed every 4 hours after the
system is powered up and every time the system is armed. This output is reset only after a
Dynamic Battery Test reports that the backup battery voltage is normal.
1,6 Horn Speaker Monitor Fail
If the Enable Monitoring of Horn Speaker option (2) in Location 492 is selected or option
“Horner Speaker Fault Monitor” (TEXT Codepad Menu 3-4-3) is enabled, this output operates
when the horn speaker is disconnected. The output is reset when the horn speaker is
reconnected.
1,7 Sensor Watch Alarm
This output operates when the Sensor Watch fault occurs. The output is reset when this fault
clears.
1,8 Codepad Medical Alarm
This output operates when a user activates a Codepad Medical Alarm by pressing [7] and [9]
at the same time on the remote codepad. This output is reset when a valid User Code is
entered at the remote codepad.
1,9 Codepad Fire Alarm
This output operates when a user activates a Codepad Medical Alarm by pressing [4] and [6]
at the same time on the remote codepad. This output is reset when a valid User Code is
entered at the remote codepad.
1,10 Panic Alarm
This output operates when a user activates a Codepad Panic Alarm by pressing either [1] and
[3] or [STAY] and [AWAY] at the same time on the remote codepad , or when a keyfob Panic
Alarm is activated by pressing ARM button and DISARM button together on the learned keyfob.
This output is reset when a valid User Code is entered at the remote codepad, or ARM or
DISARM button on the keyfob is pressed to reset alarm.
1,11 Codepad Duress Alarm
This output operates when a user activates a Duress Alarm by adding a 9 to the end of the
User Code used to disarm the system. This output is reset the next time the system is armed.
1,12 Codepad PIN Error – Access Denied
This output operates when the wrong code is entered more times than allowed. The number
of incorrect attempts allowed is programmed in Location 424 or TEXT codepad option "Access
Retry" (Menu 2-3). This output is reset when a valid User Code is entered after the codepad is
unlocked.
1,14 Horn Speaker (Output 1 Only)
This output operates only on Output 1. Use this output for one or two 8 Ω horn speakers.
To enable monitoring of the horn speaker, select Option 2 in Location 492.
1,15 Sirens Running
This output operates for the duration of the Siren Run Time programmed in Location 479.
When the sirens are activated, this output is reset when the Siren Run Time expires. The relay
output (Output 4) is set by default for this operation.
2,0 Strobe Operating
This output operates when an alarm occurs and is reset when a valid User Code is entered.
The strobe output (Output 3) is set by default for strobe operation and is programmed to
reset automatically after 8 hours.