Notice!
If automatic Test Reports are not required, program the Hour/Minute/Repeat Interval in
Locations 428 to 431 and 434 as 0.
Item Location Default
Hour of day (tens digit) 428 0
Hour of day (units digit) 429 0
Minute of day (tens digit) 430 0
Minute of day (units digit) 431 0
Repeat interval in days 434 0
Test Reporting Options
Location 435 is set by default to report only to Receiver 1. You can select whether Test
Reports are sent to Receiver 1, Receiver 2, or both, Receiver 2 only when Receiver 1 fails, or
no reporting.
Item Location Default
Test Reporting Communicator Options 435 1
Value Description
0 No Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
STAY Mode 2 Automatically Bypass Zones
STAY Mode 2 Automatically Bypass Zones can be programmed in Location 381-384. It can also
be done by master code function. Refer to Setting STAY Mode 2 Bypass Zones, page 66 for more
information.
Item Location Option Default New
STAY Mode 2
Automatically Bypass
Zones
0381 1 = Zone 1
2 = Zone 2
4 = Zone 3
8 = Zone 4
0
0382 1 = Zone 5
2 = Zone 6
4 = Zone 7
8 = Zone 8
0
9.6.3
9.7
Control Panel Zone Information | en 99
Installation Guide 2014.07 | 00n | F01U298026