LEDs
Three LEDs provide status and troubleshooting information about the module and its
connection.
LED Description
Heartbeat Indicates the system status of the B450 and its connection to the
control panel.
RX Indicates when an inbound packet is received on the bus.
TX Indicates when an outbound packet is transmitted on the bus.
Mounting considerations
Find a location with acceptable signal strength on your wireless network. Mount the B450
Conettix Plug-in Communicator Interface into the interior of a compatible enclosure via the 3-
hole mounting pattern using the supplied mounting screws.
Wiring considerations
The B450 connects to a control panel using a data bus connection via the module’s terminal
strip, or the module’s interconnect wiring connectors.
For data bus powered installations outside the compatible control panel enclosure, follow the
maximum wiring distances in the technical specifications. For further installations power from
a compatible auxiliary power supply.
Using the network communication modules
Location 81 enables/disables the external network module 1.
Location 82 enables/disables the external network module 2.
If with text codepad, go to menu 721 Network Module to enable/disable the network module.
When the value of the location above is 0, the external network module is disabled
accordingly.
When the value is 1, the corresponding network module is enabled, but the control panel
won't configure parameters of network module.
When the value is 2, the corresponding network module is enabled, and the control panel will
configure the relevant parameters to network module.
Location 81
Location 82 Reports to
Receiver 1
Reports to
Receiver 2
Will control panel configure
parameters of Network
Module?
Value = 0 Value = 0 No report will be sent by
network module.
No
Value = 1 Value = 0 Sent by network module1 No
Value = 2 Value = 0 Configure Network Module 1
Value = 1 Value = 1 Sent by
network
module 1
Sent by
network
module 2
No
Value = 1 Value = 2 Configure Network Module 2
Value = 2 Value = 1 Configure Network 1
Value = 2 Value = 2 Configure Both Network
Modules