29-4 Camera Handler Release Notes
From the table above, the resolution on both H.264 stream 2 and MJPEG stream must be
equal or less than H.264 stream 1. This means, when changing H.264 stream 1 resolution to
a smaller one, ensure it is equal to or less than the resolution on both H.264 stream 2 and
MJPEG stream.
Due to a camera limitation, if the user starts MJPEG stream or H.264 stream2 with HD
resolution, please make sure H.264 stream 1 resolution is equal to or higher than the resolution
on MJPEG stream or H.264 stream 2.
Bosch has implemented the CGI to get the Camera Type instead of the Model name labeled on
the camera. So the Camera Type is shown in the model list on the NVR.
Bosch cameras do not support changing the Video Standard, only viewing the Standard. Bosch
cameras have 3 Video Standards: NTSC, PAL and HD. If the camera video standard is HD,
“UNKNOWN” will be displayed on the NVR Camera Image Settings page.
When setting up Dry Contacts on NBN-921-P IVA serials and NBN-498 serials, it is necessary to
activate the Alarm Inputs on the camera GUI first. Users must change the Active dropdown list
value from 'None' to 'N.O.' or 'N.C.' on the camera, as 'None' means disabled and this does not
automatically change when Dry Contacts are activated on the NVR.
Due to a camera limitation, for Bosch Dinion HD 1080P D/N IVA, if the users sets stream 1
codec H.264 and 30 FPS, stream 2 codec H.264 then the streams can only reach 10 FPS, due
to stream 2 being dependent on stream 1.
Handler supports Generic functions including dual stream and audio stream with the following
limitations:
Cameras need to provide three streams, including two H.264 streams and one
MJPEG stream. So the handler can support dual H.264 streams or one H.264
stream and one MJPEG stream.
Resolution list includes HD resolution (1080P and 720P) and SD resolution (CIF
and 4CIF), but cameras may only support one or several of them.
Audio codec G711 can be supported by the audio stream, other codecs are not
supported.
It is found that different camera firmware versions can return different camera types. This causes
the handler to recognize the camera as Generic camera. Please ensure the Bosch camera has
the recommended firmware version before adding it to the NVR.
Due to camera limitations on the AutoDome Jr 800 HD, it supports single H.264 stream when the
resolution is set to 1080P or 720P 50 (PAL)/60 (NTSC) FPS on H.264 stream 1, and H.264
stream 2 is only a copy of H.264 stream 1 when 1080P is selected for stream 1. It supports dual
H.264 streams when resolution and FPS are set to 720P and 25 (PAL)/30 (NTSC) FPS or below,
and H.264 stream 2 can be set to 4CIF and CIF resolution.
1920x1080
1280x720
4CIF
704x432
512x288
CIF
256x144
1280x720 1280x720
4CIF
704x432
512x288
CIF
256x144
1280x720
4CIF
704x432
512x288
CIF
256x144
1920x1080
1280x720
4CIF
704x432
512x288
CIF
256x144
4CIF or below 4CIF
704x432
512x288
CIF
256x144
4CIF
704x432
512x288
CIF
256x144